Filtered by vendor Schneider-electric
Subscribe
Total
675 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-7520 | 1 Schneider-electric | 1 Software Update Utility | 2020-07-28 | 4.0 MEDIUM | 4.7 MEDIUM |
A CWE-601: URL Redirection to Untrusted Site ('Open Redirect') vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim's machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker's possession. A man-in-the-middle attack is then used to complete the exploit. | |||||
CVE-2020-7517 | 1 Schneider-electric | 1 Easergy Builder | 2020-07-27 | 2.1 LOW | 5.5 MEDIUM |
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials. | |||||
CVE-2020-7514 | 1 Schneider-electric | 1 Easergy Builder | 2020-07-27 | 4.6 MEDIUM | 7.8 HIGH |
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker access to the authorization credentials for a device and gain full access. | |||||
CVE-2020-7518 | 1 Schneider-electric | 1 Easergy Builder | 2020-07-27 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-20: Improper input validation vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to modify project configuration files. | |||||
CVE-2020-7519 | 1 Schneider-electric | 1 Easergy Builder | 2020-07-27 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account. | |||||
CVE-2012-0931 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2020-07-23 | 7.5 HIGH | 9.8 CRITICAL |
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors. | |||||
CVE-2012-0929 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2020-07-23 | 7.8 HIGH | 7.5 HIGH |
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server. | |||||
CVE-2012-0930 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2020-07-23 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2020-7492 | 1 Schneider-electric | 1 Gp-pro Ex Firmware | 2020-06-24 | 4.3 MEDIUM | 6.5 MEDIUM |
A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded. | |||||
CVE-2020-7497 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2020-06-19 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts. | |||||
CVE-2020-7495 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2020-06-19 | 4.3 MEDIUM | 5.5 MEDIUM |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when opening the project file. | |||||
CVE-2020-7494 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2020-06-19 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file. | |||||
CVE-2020-7512 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-19 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component. | |||||
CVE-2020-7509 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 6.5 MEDIUM | 7.2 HIGH |
A CWE-269: Improper privilege management (write) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to elevate their privileges and delete files. | |||||
CVE-2020-7508 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 5.0 MEDIUM | 9.8 CRITICAL |
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force. | |||||
CVE-2020-7505 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 9.0 HIGH | 7.2 HIGH |
A CWE-494 Download of Code Without Integrity Check vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to inject data with dangerous content into the firmware and execute arbitrary code on the system. | |||||
CVE-2020-7504 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
A CWE-20: Improper Input Validation vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to disable the webserver service on the device when specially crafted network packets are sent. | |||||
CVE-2020-7493 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2020-06-17 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file. | |||||
CVE-2020-7513 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to intercept traffic and read configuration data. | |||||
CVE-2020-7507 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-400: Uncontrolled Resource Consumption vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to login multiple times resulting in a denial of service. |