Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "http://www.securityfocus.com/bid/51605", "name": "51605", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "BID"}, {"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf", "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf", "tags": ["Broken Link"], "refsource": "MISC"}, {"url": "http://secunia.com/advisories/47723", "name": "47723", "tags": ["Not Applicable"], "refsource": "SECUNIA"}, {"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589", "name": "schneider-modicon-ftp-dos(72589)", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "XF"}, {"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588", "name": "schneider-modicon-http-dos(72588)", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "XF"}, {"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03", "name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03", "tags": ["Third Party Advisory", "US Government Resource"], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-119"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2012-0929", "ASSIGNER": "cve@mitre.org"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 7.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "NONE"}, "severity": "HIGH", "impactScore": 6.9, "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}}, "publishedDate": "2012-01-28T01:55Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_quantum_plc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2020-07-23T17:42Z"}