Filtered by vendor Schneider-electric
Subscribe
Total
675 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-7564 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP. | |||||
CVE-2019-10981 | 1 Schneider-electric | 2 Citectscada, Scada Expert Vijeo Citect | 2020-10-02 | 2.1 LOW | 7.8 HIGH |
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. | |||||
CVE-2018-7788 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2020-09-28 | 4.0 MEDIUM | 6.5 MEDIUM |
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. | |||||
CVE-2018-7824 | 2 Microsoft, Schneider-electric | 3 Windows, Driver Suite, Modbus Serial Driver | 2020-09-28 | 6.8 MEDIUM | 4.9 MEDIUM |
An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files. | |||||
CVE-2020-7528 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which could allow arbitrary code execution when an attacker builds a custom .PRJ file containing a malicious serialized buffer. | |||||
CVE-2020-7529 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 4.3 MEDIUM | 5.5 MEDIUM |
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file. | |||||
CVE-2020-7531 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user. | |||||
CVE-2020-7532 | 1 Schneider-electric | 1 Scadapack X70 Security Administrator | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack x70 Security Administrator (V1.2.0 and prior) which could allow arbitrary code execution when an attacker builds a custom .SDB file containing a malicious serialized buffer. | |||||
CVE-2018-1124 | 6 Canonical, Debian, Opensuse and 3 more | 9 Ubuntu Linux, Debian Linux, Leap and 6 more | 2020-09-09 | 4.6 MEDIUM | 7.8 HIGH |
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users. | |||||
CVE-2020-7521 | 1 Schneider-electric | 1 Apc Easy Ups Online Software | 2020-09-04 | 7.5 HIGH | 9.8 CRITICAL |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories. | |||||
CVE-2020-7522 | 1 Schneider-electric | 1 Apc Easy Ups Online Software | 2020-09-04 | 7.5 HIGH | 9.8 CRITICAL |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories. | |||||
CVE-2020-7525 | 1 Schneider-electric | 4 Spacelynk, Spacelynk Firmware, Wiser For Knx and 1 more | 2020-09-04 | 5.0 MEDIUM | 7.5 HIGH |
Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used. | |||||
CVE-2020-7527 | 1 Schneider-electric | 1 Somove | 2020-09-04 | 4.6 MEDIUM | 7.8 HIGH |
Incorrect Default Permission vulnerability exists in SoMove (V2.8.1) and prior which could cause elevation of privilege and provide full access control to local system users to SoMove component and services when a SoMove installer script is launched. | |||||
CVE-2018-7793 | 1 Schneider-electric | 4 Foxboro Dcs, Foxboro Evo, Foxview and 1 more | 2020-08-24 | 4.6 MEDIUM | 8.7 HIGH |
A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission. | |||||
CVE-2018-7816 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2020-08-24 | 5.5 MEDIUM | 6.5 MEDIUM |
A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file. | |||||
CVE-2019-6815 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2020-08-24 | 6.4 MEDIUM | 9.1 CRITICAL |
In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. | |||||
CVE-2018-7803 | 1 Schneider-electric | 1 Triconex Tristation Emulator | 2020-08-24 | 4.3 MEDIUM | 5.9 MEDIUM |
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant. | |||||
CVE-2018-7831 | 1 Schneider-electric | 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more | 2020-08-24 | 4.3 MEDIUM | 8.8 HIGH |
An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on the web server. | |||||
CVE-2018-7779 | 1 Schneider-electric | 6 Homelynk, Homelynk Firmware, Spacelynk and 3 more | 2020-08-24 | 5.0 MEDIUM | 7.5 HIGH |
In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access. | |||||
CVE-2018-7814 | 1 Schneider-electric | 1 Guicon | 2020-08-24 | 6.8 MEDIUM | 7.8 HIGH |
A Stack-based Buffer Overflow (CWE-121) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) which could cause remote code to be executed when parsing a GD1 file |