CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-9635 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2019-10-09 | 1.9 LOW | 3.9 LOW |
Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
CVE-2017-9637 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2019-10-09 | 1.9 LOW | 4.1 MEDIUM |
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
CVE-2017-6021 | 2 Aveva, Schneider-electric | 2 Clearscada, Clearscada | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | |||||
CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | |||||
CVE-2017-6033 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. | |||||
CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | |||||
CVE-2017-13997 | 1 Schneider-electric | 2 Wonderware Indusoft Web Studio, Wonderware Intouch | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. | |||||
CVE-2015-6462 | 1 Schneider-electric | 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. | |||||
CVE-2015-6461 | 1 Schneider-electric | 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more | 2019-10-09 | 5.5 MEDIUM | 5.4 MEDIUM |
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. | |||||
CVE-2015-1014 | 1 Schneider-electric | 3 Citectscada, Opc Factory Server, Scada Expert Vijeo Citect | 2019-10-09 | 4.4 MEDIUM | 7.3 HIGH |
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. | |||||
CVE-2017-9967 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2019-10-02 | 4.6 MEDIUM | 7.8 HIGH |
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security. | |||||
CVE-2018-7785 | 1 Schneider-electric | 1 U.motion Builder | 2019-10-02 | 7.5 HIGH | 9.8 CRITICAL |
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass. | |||||
CVE-2017-5155 | 1 Schneider-electric | 1 Wonderware Historian | 2019-10-02 | 7.5 HIGH | 7.3 HIGH |
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well. | |||||
CVE-2018-7770 | 1 Schneider-electric | 1 U.motion | 2019-10-02 | 4.3 MEDIUM | 6.5 MEDIUM |
The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. | |||||
CVE-2018-7781 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2019-10-02 | 4.0 MEDIUM | 8.8 HIGH |
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation. | |||||
CVE-2017-7972 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2019-10-02 | 5.2 MEDIUM | 5.5 MEDIUM |
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes. | |||||
CVE-2017-7966 | 1 Schneider-electric | 1 Somachine | 2019-10-02 | 6.8 MEDIUM | 8.8 HIGH |
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. | |||||
CVE-2017-7970 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2019-10-02 | 3.3 LOW | 6.5 MEDIUM |
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components. | |||||
CVE-2017-8371 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2019-10-02 | 4.0 MEDIUM | 6.8 MEDIUM |
Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. | |||||
CVE-2018-7782 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2019-10-02 | 4.0 MEDIUM | 8.8 HIGH |
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text. |