CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2016-5818 | 1 Schneider-electric | 2 Powerlogic Pm8ecc, Powerlogic Pm8ecc Firmware | 2017-02-17 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device. | |||||
CVE-2014-9200 | 1 Schneider-electric | 4 Somachine, Somove, Somove Lite and 1 more | 2016-12-30 | 7.5 HIGH | N/A |
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
CVE-2015-3940 | 1 Schneider-electric | 1 Wonderware System Platform 2014 | 2016-12-23 | 6.9 MEDIUM | N/A |
Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. | |||||
CVE-2016-4520 | 1 Schneider-electric | 1 Pelco Digital Sentry Video Management System Firmware | 2016-11-28 | 10.0 HIGH | 9.8 CRITICAL |
Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors. | |||||
CVE-2015-7937 | 1 Schneider-electric | 13 Bmxnoc0401, Bmxnoe0100, Bmxnoe0100h and 10 more | 2016-11-28 | 10.0 HIGH | N/A |
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data. | |||||
CVE-2014-9206 | 1 Schneider-electric | 1 Device Type Manager | 2016-08-26 | 6.9 MEDIUM | N/A |
Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file. | |||||
CVE-2016-4513 | 1 Schneider-electric | 2 Powerlogic Pm8ecc, Powerlogic Pm8ecc Firmware | 2016-06-28 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2015-8561 | 1 Schneider-electric | 1 Proclima | 2015-12-16 | 6.8 MEDIUM | N/A |
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918. | |||||
CVE-2015-7918 | 1 Schneider-electric | 1 Proclima | 2015-12-16 | 6.8 MEDIUM | N/A |
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561. | |||||
CVE-2015-3977 | 1 Schneider-electric | 1 Imt25 Magnetic Flow Dtm | 2015-11-16 | 7.7 HIGH | N/A |
Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply. | |||||
CVE-2014-0774 | 1 Schneider-electric | 6 Ofs Test Client Tlxcdlfofs33, Ofs Test Client Tlxcdltofs33, Ofs Test Client Tlxcdluofs33 and 3 more | 2015-10-16 | 6.9 MEDIUM | N/A |
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file. | |||||
CVE-2014-8511 | 1 Schneider-electric | 1 Proclima | 2015-02-02 | 10.0 HIGH | N/A |
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers. | |||||
CVE-2014-9197 | 1 Schneider-electric | 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more | 2015-01-28 | 7.8 HIGH | N/A |
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. | |||||
CVE-2014-9190 | 1 Schneider-electric | 1 Wonderware Intouch Access Anywhere Server | 2015-01-12 | 10.0 HIGH | N/A |
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist. | |||||
CVE-2014-5407 | 1 Schneider-electric | 1 Vampset | 2014-09-15 | 4.4 MEDIUM | N/A |
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file. | |||||
CVE-2014-0789 | 1 Schneider-electric | 5 Opc Factory Server Tlxcdlfofs, Opc Factory Server Tlxcdltofs, Opc Factory Server Tlxcdluofs and 2 more | 2014-04-04 | 7.8 HIGH | N/A |
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions. | |||||
CVE-2014-0759 | 1 Schneider-electric | 1 Floating License Manager | 2014-02-28 | 6.9 MEDIUM | N/A |
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character. | |||||
CVE-2013-2824 | 1 Schneider-electric | 4 Citectscada, Powerlogic Scada, Struxureware Powerscada Expert and 1 more | 2014-02-26 | 7.8 HIGH | N/A |
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. | |||||
CVE-2013-6143 | 1 Schneider-electric | 1 Telvent Sage 3030 Firmware | 2014-02-10 | 5.0 MEDIUM | N/A |
The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic. | |||||
CVE-2013-2782 | 1 Schneider-electric | 2 Tburjr900, Tburjr900 Firmware | 2013-08-29 | 9.3 HIGH | N/A |
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |