Filtered by vendor Schneider-electric
Subscribe
Total
675 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-7764 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 4.3 MEDIUM | 4.3 MEDIUM |
The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet. | |||||
CVE-2018-7771 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 6.0 MEDIUM | 8.0 HIGH |
The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A directory traversal vulnerability allows a caller with standard user privileges to write arbitrary php files anywhere in the web service directory tree. | |||||
CVE-2018-7773 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-23 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the sessionid input parameter. | |||||
CVE-2018-7767 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-21 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter. | |||||
CVE-2018-7769 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-21 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter. | |||||
CVE-2018-7774 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-21 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter. | |||||
CVE-2018-7768 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-21 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the tpl input parameter. | |||||
CVE-2018-7766 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-21 | 6.8 MEDIUM | 8.8 HIGH |
The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter. | |||||
CVE-2013-0657 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2018-08-21 | 10.0 HIGH | N/A |
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol. | |||||
CVE-2018-7758 | 1 Schneider-electric | 46 Micom P141, Micom P141 Firmware, Micom P142 and 43 more | 2018-05-29 | 3.3 LOW | 6.5 MEDIUM |
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number. | |||||
CVE-2018-7762 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2018-05-24 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. | |||||
CVE-2018-7761 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2018-05-24 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. | |||||
CVE-2018-7760 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2018-05-24 | 7.5 HIGH | 9.8 CRITICAL |
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization. | |||||
CVE-2018-7759 | 1 Schneider-electric | 114 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 111 more | 2018-05-24 | 5.0 MEDIUM | 7.5 HIGH |
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. | |||||
CVE-2013-0663 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2018-05-23 | 6.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials. | |||||
CVE-2018-7244 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2018-05-23 | 5.0 MEDIUM | 5.3 MEDIUM |
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained. | |||||
CVE-2016-5809 | 1 Schneider-electric | 6 Ion5000, Ion7300, Ion7500 and 3 more | 2018-05-19 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved. | |||||
CVE-2018-7239 | 1 Schneider-electric | 13 Atv12 Dtm, Atv212 Dtm, Atv312 Dtm and 10 more | 2018-03-26 | 6.8 MEDIUM | 7.8 HIGH |
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code. | |||||
CVE-2017-9970 | 1 Schneider-electric | 1 Struxureon Gateway | 2018-03-09 | 9.0 HIGH | 7.2 HIGH |
A remote code execution vulnerability exists in Schneider Electric's StruxureOn Gateway versions 1.1.3 and prior. Uploading a zip which contains carefully crafted metadata allows for the file to be uploaded to any directory on the host machine information which could lead to remote code execution. | |||||
CVE-2017-9968 | 1 Schneider-electric | 1 Igss Mobile | 2018-03-09 | 4.3 MEDIUM | 5.9 MEDIUM |
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack. |