Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf", "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf", "tags": ["US Government Resource"], "refsource": "MISC"}, {"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper", "name": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf&reference=SEVD-2013-023-01&docType=Technical-paper", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/", "name": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "https://www.exploit-db.com/exploits/44678/", "name": "44678", "tags": [], "refsource": "EXPLOIT-DB"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-352"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2013-0663", "ASSIGNER": "ics-cert@hq.dhs.gov"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "impactScore": 6.4, "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}}, "publishedDate": "2013-04-04T11:58Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_quantum_plc:140noe77101:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_quantum_plc:140nwm10000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_quantum_plc:140noe77111:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m340:bmxnoe0100x:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m340:bmxnoe011xx:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m340:bmxnoc0401:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_premium:tsxety5103:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_premium:tsxwmy100:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_premium:tsxety4103:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2018-05-24T01:29Z"}