CVE-2018-7758

A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number.
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p141_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p141:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p142_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p142:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p143_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p143:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p145_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p145:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p642_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p642:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p643_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p643:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p645_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p645:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p849_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p849:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p746_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p746:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p841a_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p841a:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p841b_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p841b:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p443_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p443:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p445_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p445:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p446_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p446:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p441_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p441:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p442_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p442:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p444_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p444:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p541_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p541:-:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p542_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p542:-:*:*:*:*:*:*:*

Configuration 20 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p543_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p543:-:*:*:*:*:*:*:*

Configuration 21 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p544_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p544:-:*:*:*:*:*:*:*

Configuration 22 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p545_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p545:-:*:*:*:*:*:*:*

Configuration 23 (hide)

AND
cpe:2.3:o:schneider-electric:micom_p546_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_p546:-:*:*:*:*:*:*:*

Information

Published : 2018-04-18 13:29

Updated : 2018-05-29 06:59


NVD link : CVE-2018-7758

Mitre link : CVE-2018-7758


JSON object : View

CWE
CWE-613

Insufficient Session Expiration

Advertisement

dedicated server usa

Products Affected

schneider-electric

  • micom_p546_firmware
  • micom_p143
  • micom_p849
  • micom_p841b
  • micom_p445
  • micom_p442
  • micom_p445_firmware
  • micom_p645_firmware
  • micom_p443
  • micom_p746_firmware
  • micom_p545
  • micom_p544_firmware
  • micom_p145
  • micom_p841b_firmware
  • micom_p643_firmware
  • micom_p841a
  • micom_p542_firmware
  • micom_p545_firmware
  • micom_p543_firmware
  • micom_p145_firmware
  • micom_p542
  • micom_p444_firmware
  • micom_p841a_firmware
  • micom_p544
  • micom_p141
  • micom_p444
  • micom_p441_firmware
  • micom_p541_firmware
  • micom_p849_firmware
  • micom_p142
  • micom_p746
  • micom_p442_firmware
  • micom_p142_firmware
  • micom_p443_firmware
  • micom_p643
  • micom_p143_firmware
  • micom_p642_firmware
  • micom_p543
  • micom_p546
  • micom_p441
  • micom_p645
  • micom_p141_firmware
  • micom_p541
  • micom_p446
  • micom_p446_firmware
  • micom_p642