CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-6015 | 1 Rockwellautomation | 1 Factorytalk Activation | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later. | |||||
CVE-2017-5176 | 1 Rockwellautomation | 8 9328-ccwdevdee, 9328-ccwdevene, 9328-ccwdevese and 5 more | 2019-10-09 | 6.2 MEDIUM | 7.0 HIGH |
A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. | |||||
CVE-2017-14022 | 1 Rockwellautomation | 1 Factorytalk Alarms And Events | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate. | |||||
CVE-2017-7899 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2019-10-02 | 5.0 MEDIUM | 9.8 CRITICAL |
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval. | |||||
CVE-2017-7898 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2019-10-02 | 5.0 MEDIUM | 9.8 CRITICAL |
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords. | |||||
CVE-2012-6442 | 1 Rockwellautomation | 22 1100, 1400, 1756-enbt and 19 more | 2019-09-03 | 7.8 HIGH | N/A |
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 allow remote attackers to cause a denial of service (control and communication outage) via a CIP message that specifies a reset. | |||||
CVE-2018-19282 | 1 Rockwellautomation | 2 Powerflex 525 Ac Drives, Powerflex 525 Ac Drives Firmware | 2019-04-09 | 10.0 HIGH | 9.8 CRITICAL |
Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control. | |||||
CVE-2009-3739 | 1 Rockwellautomation | 2 Ab Micrologix Controller 1100, Ab Micrologix Controller 1400 | 2018-10-10 | 10.0 HIGH | N/A |
Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors. | |||||
CVE-2017-9312 | 1 Rockwellautomation | 2 Allen-bradley L30erms, Allen-bradley L30erms Firmware | 2018-08-23 | 7.8 HIGH | 7.5 HIGH |
Improperly implemented option-field processing in the TCP/IP stack on Allen-Bradley L30ERMS safety devices v30 and earlier causes a denial of service. When a crafted TCP packet is received, the device reboots immediately. | |||||
CVE-2017-16740 | 1 Rockwellautomation | 12 1766-l32awa, 1766-l32awa Firmware, 1766-l32awaa and 9 more | 2018-08-16 | 7.5 HIGH | 10.0 CRITICAL |
A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. | |||||
CVE-2016-2279 | 1 Rockwellautomation | 15 Compactlogix 1769-l16er-bb1b, Compactlogix 1769-l18er-bb1b, Compactlogix 1769-l18erm-bb1b and 12 more | 2018-05-19 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the web server in Rockwell Automation Allen-Bradley CompactLogix 1769-L* before 28.011+ allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
CVE-2011-2530 | 1 Rockwellautomation | 2 Eds Hardware Installation Tool, Rslinx | 2018-04-10 | 9.3 HIGH | N/A |
Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file. | |||||
CVE-2014-9204 | 1 Rockwellautomation | 1 Rslinx | 2018-04-10 | 6.9 MEDIUM | N/A |
Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers to execute arbitrary code via a crafted CSV file. | |||||
CVE-2014-0755 | 1 Rockwellautomation | 2 Logix 5000 Controller, Rslogix 5000 Design And Configuration Software | 2017-08-28 | 6.9 MEDIUM | N/A |
Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors. | |||||
CVE-2011-3489 | 1 Rockwellautomation | 1 Rslogix | 2017-08-28 | 5.0 MEDIUM | N/A |
RnaUtility.dll in RsvcHost.exe 2.30.0.23 in Rockwell RSLogix 19 and earlier allows remote attackers to cause a denial of service (crash) via a crafted rna packet with a long string to TCP port 4446 that triggers (1) "a memset zero overflow" or (2) an out-of-bounds read, related to improper handling of a 32-bit size field. | |||||
CVE-2017-7903 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2017-07-07 | 5.0 MEDIUM | 9.8 CRITICAL |
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password. | |||||
CVE-2017-7901 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2017-07-07 | 9.0 HIGH | 8.6 HIGH |
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device. | |||||
CVE-2016-9338 | 1 Rockwellautomation | 20 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 17 more | 2017-03-16 | 4.0 MEDIUM | 2.7 LOW |
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller. | |||||
CVE-2016-9334 | 1 Rockwellautomation | 20 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 17 more | 2017-03-16 | 5.0 MEDIUM | 7.3 HIGH |
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. User credentials are sent to the web server in clear text, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server. | |||||
CVE-2016-0868 | 1 Rockwellautomation | 9 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 6 more | 2016-12-22 | 10.0 HIGH | 9.8 CRITICAL |
Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request. |