CVE-2017-7899

An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.
References
Link Resource
https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04 Patch Third Party Advisory US Government Resource
http://www.securitytracker.com/id/1038546
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*

Information

Published : 2017-06-29 20:29

Updated : 2019-10-02 17:03


NVD link : CVE-2017-7899

Mitre link : CVE-2017-7899


JSON object : View

CWE
CWE-200

Exposure of Sensitive Information to an Unauthorized Actor

Advertisement

dedicated server usa

Products Affected

rockwellautomation

  • 1763-l16dwd_series_a
  • ab_micrologix_controller
  • 1766-l32bwaa_series_a
  • 1763-l16bwa_series_a
  • 1766-l32bwa_series_a
  • 1766-l32awaa_series_b
  • 1766-l32bxb_series_a
  • 1763-l16bwa_series_b
  • 1766-l32awa_series_a
  • 1763-l16bbb_series_a
  • 1766-l32awa_series_b
  • 1763-l16awa_series_a
  • 1766-l32bxb_series_b
  • 1763-l16dwd_series_b
  • 1766-l32bwaa_series_b
  • 1763-l16awa_series_b
  • 1763-l16bbb_series_b
  • 1766-l32bxba_series_a
  • 1766-l32bxba_series_b
  • 1766-l32awaa_series_a
  • 1766-l32bwa_series_b