Filtered by vendor Siemens
Subscribe
Total
1529 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-25228 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-12-16 | 10.0 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. | |||||
CVE-2020-25230 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-12-16 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device. | |||||
CVE-2020-25231 | 1 Siemens | 3 Logo\! 8 Bm, Logo\! 8 Bm Firmware, Logo\! Soft Comfort | 2020-12-16 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program files. | |||||
CVE-2020-25232 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-12-16 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp. | |||||
CVE-2020-25233 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-12-16 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. | |||||
CVE-2020-25234 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-12-16 | 3.6 LOW | 7.7 HIGH |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions (UDF) in a password protected way. This protection is implemented in the software that displays the information. An attacker could reverse engineer the UDFs directly from stored program files. | |||||
CVE-2020-25235 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2020-12-16 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins. | |||||
CVE-2019-19283 | 1 Siemens | 1 Xhq | 2020-12-15 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in XHQ (All Versions < 6.1). The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place. | |||||
CVE-2019-19287 | 1 Siemens | 1 Xhq | 2020-12-15 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow attackers to traverse through the file system of the server based by sending specially crafted packets over the network without authentication. | |||||
CVE-2019-19289 | 1 Siemens | 1 Xhq | 2020-12-15 | 6.8 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. | |||||
CVE-2019-19286 | 1 Siemens | 1 Xhq | 2020-12-15 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow SQL injection attacks if an attacker is able to modify content of particular web pages. | |||||
CVE-2019-19284 | 1 Siemens | 1 Xhq | 2020-12-15 | 3.5 LOW | 5.4 MEDIUM |
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. | |||||
CVE-2019-19288 | 1 Siemens | 1 Xhq | 2020-12-15 | 4.3 MEDIUM | 6.1 MEDIUM |
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. | |||||
CVE-2020-15791 | 1 Siemens | 28 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 312 Firmware, Simatic S7-300 Cpu 314 and 25 more | 2020-12-14 | 3.3 LOW | 6.5 MEDIUM |
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials. | |||||
CVE-2018-4833 | 1 Siemens | 18 Rfid 181-eip, Rfid 181-eip Firmware, Ruggedcom Wimax and 15 more | 2020-12-14 | 5.8 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request. | |||||
CVE-2020-7590 | 1 Siemens | 2 Dca Vantage Analyzer, Dca Vantage Analyzer Firmware | 2020-10-29 | 4.6 MEDIUM | 6.8 MEDIUM |
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device. | |||||
CVE-2020-15797 | 1 Siemens | 2 Dca Vantage Analyzer, Dca Vantage Analyzer Firmware | 2020-10-28 | 7.2 HIGH | 6.8 MEDIUM |
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Improper Access Control could allow an unauthenticated attacker to escape from the restricted environment (“kiosk mode”) and access the underlying operating system. Successful exploitation requires direct physical access to the system. | |||||
CVE-2019-8274 | 2 Siemens, Uvnc | 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more | 2020-10-22 | 7.5 HIGH | 9.8 CRITICAL |
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212. | |||||
CVE-2019-8273 | 2 Siemens, Uvnc | 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more | 2020-10-22 | 7.5 HIGH | 9.8 CRITICAL |
UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212. | |||||
CVE-2019-8276 | 2 Siemens, Uvnc | 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more | 2020-10-22 | 5.0 MEDIUM | 7.5 HIGH |
UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212. |