{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf", "tags": ["Vendor Advisory"], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-122"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2018-4833", "ASSIGNER": "productcert@siemens.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 5.8, "accessVector": "ADJACENT_NETWORK", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "impactScore": 6.4, "obtainAllPrivilege": false, "exploitabilityScore": 6.5, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 8.8, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}}, "publishedDate": "2018-06-14T16:29Z", "configurations": {"nodes": [{"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:rfid_181-eip_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:rfid_181-eip:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_wimax_firmware:4.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_wimax_firmware:4.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_wimax:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.2.3"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.4.1"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:scalance_x200irt:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204rna_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204rna:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:scalance_x300_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:scalance_x408_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:scalance_x414_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_rf182c_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2020-12-14T21:15Z"}