Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01", "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-634", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-634", "tags": [], "refsource": "MISC"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-631", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-631", "tags": [], "refsource": "MISC"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-625", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-625", "tags": [], "refsource": "MISC"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-635", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-635", "tags": [], "refsource": "MISC"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02", "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02", "tags": ["Third Party Advisory", "US Government Resource"], "refsource": "MISC"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-630", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-630", "tags": [], "refsource": "MISC"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-632", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-632", "tags": [], "refsource": "MISC"}, {"url": "http://www.zerodayinitiative.com/advisories/ZDI-15-633", "name": "http://www.zerodayinitiative.com/advisories/ZDI-15-633", "tags": [], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-119"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2015-7918", "ASSIGNER": "ics-cert@hq.dhs.gov"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "impactScore": 6.4, "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}}, "publishedDate": "2015-12-15T05:59Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndIncluding": "6.1"}]}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2015-12-16T13:21Z"}