CVE-2020-16214 1 Philips 1 Patient Information Center Ix 2020-09-15 5.8 MEDIUM 5.0 MEDIUM
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
CVE-2020-16216 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2020-09-15 6.1 MEDIUM 6.5 MEDIUM
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
CVE-2020-16218 1 Philips 1 Patient Information Center Ix 2020-09-15 2.7 LOW 3.5 LOW
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
CVE-2020-16228 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2020-09-15 5.2 MEDIUM 6.4 MEDIUM
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16224 1 Philips 1 Patient Information Center Ix 2020-09-15 3.3 LOW 6.5 MEDIUM
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16222 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2020-09-15 5.8 MEDIUM 8.8 HIGH
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16220 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2020-09-15 3.3 LOW 4.3 MEDIUM
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16212 1 Philips 1 Patient Information Center Ix 2020-09-15 4.6 MEDIUM 6.8 MEDIUM
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
CVE-2020-11617 2 Philips, Thomsonstb 4 Dtr3502bfta Dvb-t2, Dtr3502bfta Dvb-t2 Firmware, Tht741fta and 1 more 2020-09-09 4.3 MEDIUM 5.9 MEDIUM
The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client.
CVE-2020-11618 2 Philips, Thomsonstb 4 Dtr3502bfta Dvb-t2, Dtr3502bfta Dvb-t2 Firmware, Tht741fta and 1 more 2020-09-09 7.2 HIGH 7.8 HIGH
THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol.
CVE-2020-14518 1 Philips 1 Dreammapper 2020-08-27 5.0 MEDIUM 5.3 MEDIUM
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
CVE-2020-16239 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2020-08-27 4.0 MEDIUM 4.9 MEDIUM
Philips SureSigns VS4, A.07.107 and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16237 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2020-08-27 2.1 LOW 2.1 LOW
Philips SureSigns VS4, A.07.107 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2019-18980 1 Philips 2 Taolight Smart Wi-fi Wiz Connected Led Bulb 9290022656, Taolight Smart Wi-fi Wiz Connected Led Bulb 9290022656 Firmware 2020-08-24 5.0 MEDIUM 7.5 HIGH
On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb's operation. Anyone can turn the bulb on or off, or change its color or brightness remotely. There is no authentication or encryption to use the control API. The only requirement is that the attacker have network access to the bulb.
CVE-2020-7360 1 Philips 1 Smartcontrol 2020-08-19 6.9 MEDIUM 7.3 HIGH
An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)
CVE-2020-14477 1 Philips 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more 2020-07-15 3.6 LOW 4.4 MEDIUM
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
CVE-2020-12023 1 Philips 1 Intellibridge Enterprise 2020-06-23 2.7 LOW 4.5 MEDIUM
Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files.
CVE-2019-18263 1 Philips 6 Endura, Endura Firmware, Pulsera and 3 more 2020-01-09 3.3 LOW 6.5 MEDIUM
An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). The router software uses an encryption scheme that is not strong enough for the level of protection required.
CVE-2019-18241 1 Philips 4 Intellibridge Ec40, Intellibridge Ec40 Firmware, Intellibridge Ec80 and 1 more 2019-12-18 3.3 LOW 6.5 MEDIUM
In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub.
CVE-2019-13557 1 Philips 2 Tasy Emr, Tasy Webportal 2019-11-13 5.0 MEDIUM 5.3 MEDIUM
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.