Filtered by vendor Philips
Subscribe
Total
100 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-6007 | 1 Philips | 2 Hue Bridge V2, Hue Bridge V2 Firmware | 2023-02-28 | 4.3 MEDIUM | 7.9 HIGH |
Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during the commissioning phase, resulting in a remote code execution. | |||||
CVE-2021-39369 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2023-01-04 | N/A | 6.5 MEDIUM |
In Philips (formerly Carestream) Vue MyVue PACS through 12.2.x.x, the VideoStream function allows Path Traversal by authenticated users to access files stored outside of the web root. | |||||
CVE-2019-6562 | 1 Philips | 1 Tasy Emr | 2022-11-30 | 3.5 LOW | 5.4 MEDIUM |
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. | |||||
CVE-2021-23173 | 1 Philips | 1 Engage | 2022-08-30 | 4.0 MEDIUM | 4.3 MEDIUM |
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data. | |||||
CVE-2021-42744 | 1 Philips | 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more | 2022-08-09 | 2.1 LOW | 5.5 MEDIUM |
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access. | |||||
CVE-2018-7580 | 1 Philips | 2 Hue, Hue Firmware | 2022-08-05 | 5.0 MEDIUM | 7.5 HIGH |
Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding. The "hub" will stop operating and be frozen until the flood stops. During the flood, the user won't be able to turn on/off the lights, and all of the hub's functionality will be unresponsive. The cloud service also won't work with the hub. | |||||
CVE-2021-26262 | 1 Philips | 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more | 2022-08-01 | 5.0 MEDIUM | 5.5 MEDIUM |
Philips MRI 1.5T and MRI 3T Version 5.x.x does not restrict or incorrectly restricts access to a resource from an unauthorized actor. | |||||
CVE-2021-27493 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-07-12 | 6.4 MEDIUM | 6.5 MEDIUM |
Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component. | |||||
CVE-2021-32966 | 1 Philips | 1 Interoperability Solution Xds | 2022-06-08 | 4.3 MEDIUM | 7.5 HIGH |
Philips Interoperability Solution XDS versions 2.5 through 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials. | |||||
CVE-2020-16247 | 1 Philips | 1 Clinical Collaboration Platform | 2022-04-25 | 3.6 LOW | 7.1 HIGH |
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. | |||||
CVE-2018-14787 | 1 Philips | 2 Intellispace Cardiovascular, Xcelera | 2022-04-22 | 4.6 MEDIUM | 7.8 HIGH |
In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions. | |||||
CVE-2018-14789 | 1 Philips | 2 Intellispace Cardiovascular, Xcelera | 2022-04-22 | 4.6 MEDIUM | 6.7 MEDIUM |
In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges. | |||||
CVE-2022-0922 | 1 Philips | 2 E-alert, E-alert Firmware | 2022-04-12 | 5.7 MEDIUM | 6.5 MEDIUM |
The software does not perform any authentication for critical system functionality. | |||||
CVE-2021-33020 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key. | |||||
CVE-2021-27497 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 7.5 HIGH | 9.8 CRITICAL |
Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product. | |||||
CVE-2021-33024 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval. | |||||
CVE-2021-33022 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. | |||||
CVE-2021-33018 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information. | |||||
CVE-2021-27501 | 1 Philips | 4 Myvue, Speech, Vue Motion and 1 more | 2022-04-08 | 7.5 HIGH | 9.8 CRITICAL |
Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities. | |||||
CVE-2021-43552 | 1 Philips | 1 Patient Information Center Ix | 2022-01-12 | 2.1 LOW | 5.5 MEDIUM |
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. |