Total
1509 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-6525 | 1 Aveva | 1 Wonderware System Platform | 2020-10-16 | 4.0 MEDIUM | 8.8 HIGH |
AVEVA Wonderware System Platform 2017 Update 2 and prior uses an ArchestrA network user account for authentication of system processes and inter-node communications. A user with low privileges could make use of an API to obtain the credentials for this account. | |||||
CVE-2019-3805 | 1 Redhat | 2 Jboss Enterprise Application Platform, Wildfly | 2020-10-16 | 4.7 MEDIUM | 4.7 MEDIUM |
A flaw was discovered in wildfly versions up to 16.0.0.Final that would allow local users who are able to execute init.d script to terminate arbitrary processes on the system. An attacker could exploit this by modifying the PID file in /var/run/jboss-eap/ allowing the init.d script to terminate any process as root. | |||||
CVE-2019-17631 | 2 Eclipse, Redhat | 7 Openj9, Enterprise Linux, Enterprise Linux Desktop and 4 more | 2020-10-16 | 6.4 MEDIUM | 9.1 CRITICAL |
From Eclipse OpenJ9 0.15 to 0.16, access to diagnostic operations such as causing a GC or creating a diagnostic file are permitted without any privilege checks. | |||||
CVE-2019-1939 | 2 Cisco, Microsoft | 2 Webex Teams, Windows | 2020-10-16 | 9.3 HIGH | 8.8 HIGH |
A vulnerability in the Cisco Webex Teams client for Windows could allow an unauthenticated, remote attacker to execute arbitrary commands on an affected system. This vulnerability is due to improper restrictions on software logging features used by the application on Windows operating systems. An attacker could exploit this vulnerability by convincing a targeted user to visit a website designed to submit malicious input to the affected application. A successful exploit could allow the attacker to cause the application to modify files and execute arbitrary commands on the system with the privileges of the targeted user. | |||||
CVE-2020-3396 | 1 Cisco | 56 Asr 1000-x, Asr 1001, Asr 1001-x and 53 more | 2020-10-15 | 6.9 MEDIUM | 7.2 HIGH |
A vulnerability in the file system on the pluggable USB 3.0 Solid State Drive (SSD) for Cisco IOS XE Software could allow an authenticated, physical attacker to remove the USB 3.0 SSD and modify sensitive areas of the file system, including the namespace container protections. The vulnerability occurs because the USB 3.0 SSD control data is not stored on the internal boot flash. An attacker could exploit this vulnerability by removing the USB 3.0 SSD, modifying or deleting files on the USB 3.0 SSD by using another device, and then reinserting the USB 3.0 SSD on the original device. A successful exploit could allow the attacker to remove container protections and perform file actions outside the namespace of the container with root privileges. | |||||
CVE-2019-14838 | 1 Redhat | 5 Data Grid, Enterprise Linux, Jboss Enterprise Application Platform and 2 more | 2020-10-13 | 4.0 MEDIUM | 4.9 MEDIUM |
A flaw was found in wildfly-core before 7.2.5.GA. The Management users with Monitor, Auditor and Deployer Roles should not be allowed to modify the runtime state of the server | |||||
CVE-2020-12757 | 1 Hashicorp | 1 Vault | 2020-10-12 | 7.5 HIGH | 9.8 CRITICAL |
HashiCorp Vault and Vault Enterprise 1.4.0 and 1.4.1, when configured with the GCP Secrets Engine, may incorrectly generate GCP Credentials with the default time-to-live lease duration instead of the engine-configured setting. This may lead to generated GCP credentials being valid for longer than intended. Fixed in 1.4.2. | |||||
CVE-2019-7479 | 1 Sonicwall | 2 Sonicos, Sonicosv | 2020-10-09 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability in SonicOS allow authenticated read-only admin can elevate permissions to configuration mode. This vulnerability affected SonicOS Gen 5 version 5.9.1.12-4o and earlier, Gen 6 version 6.2.7.4-32n, 6.5.1.4-4n, 6.5.2.3-4n, 6.5.3.3-3n, 6.2.7.10-3n, 6.4.1.0-3n, 6.5.3.3-3n, 6.5.1.9-4n and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V). | |||||
CVE-2019-1754 | 1 Cisco | 1 Ios Xe | 2020-10-08 | 9.0 HIGH | 8.8 HIGH |
A vulnerability in the authorization subsystem of Cisco IOS XE Software could allow an authenticated but unprivileged (level 1), remote attacker to run privileged Cisco IOS commands by using the web UI. The vulnerability is due to improper validation of user privileges of web UI users. An attacker could exploit this vulnerability by submitting a malicious payload to a specific endpoint in the web UI. A successful exploit could allow the lower-privileged attacker to execute arbitrary commands with higher privileges on the affected device. | |||||
CVE-2020-8247 | 1 Citrix | 5 Application Delivery Controller, Application Delivery Controller Firmware, Gateway and 2 more | 2020-10-07 | 6.5 MEDIUM | 8.8 HIGH |
Citrix ADC and Citrix Gateway 13.0 before 13.0-64.35, Citrix ADC and NetScaler Gateway 12.1 before 12.1-58.15, Citrix ADC 12.1-FIPS before 12.1-55.187, Citrix ADC and NetScaler Gateway 12.0, Citrix ADC and NetScaler Gateway 11.1 before 11.1-65.12, Citrix SD-WAN WANOP 11.2 before 11.2.1a, Citrix SD-WAN WANOP 11.1 before 11.1.2a, Citrix SD-WAN WANOP 11.0 before 11.0.3f, Citrix SD-WAN WANOP 10.2 before 10.2.7b are vulnerable to escalation of privileges on the management interface. | |||||
CVE-2015-4719 | 1 Pexip | 1 Pexip Infinity | 2020-10-07 | 7.5 HIGH | 9.8 CRITICAL |
The client API authentication mechanism in Pexip Infinity before 10 allows remote attackers to gain privileges via a crafted request. | |||||
CVE-2019-11896 | 1 Bosch | 2 Smart Home Controller, Smart Home Controller Firmware | 2020-10-06 | 6.8 MEDIUM | 7.1 HIGH |
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction. | |||||
CVE-2019-11893 | 1 Bosch | 2 Smart Home Controller, Smart Home Controller Firmware | 2020-10-06 | 4.9 MEDIUM | 8.0 HIGH |
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction. | |||||
CVE-2019-11891 | 1 Bosch | 2 Smart Home Controller, Smart Home Controller Firmware | 2020-10-06 | 5.4 MEDIUM | 8.0 HIGH |
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack. | |||||
CVE-2019-7394 | 1 Ca | 2 Risk Authentication, Strong Authentication | 2020-10-06 | 6.5 MEDIUM | 8.8 HIGH |
A privilege escalation vulnerability in the administrative user interface of CA Technologies CA Strong Authentication 9.0.x, 8.2.x, 8.1.x, 8.0.x, 7.1.x and CA Risk Authentication 9.0.x, 8.2.x, 8.1.x, 8.0.x, 3.1.x allows an authenticated attacker to gain additional privileges in some cases where an account has customized and limited privileges. | |||||
CVE-2019-10144 | 1 Redhat | 1 Rkt | 2020-09-30 | 6.9 MEDIUM | 7.7 HIGH |
rkt through version 1.30.0 does not isolate processes in containers that are run with `rkt enter`. Processes run with `rkt enter` are given all capabilities during stage 2 (the actual environment in which the applications run). Compromised containers could exploit this flaw to access host resources. | |||||
CVE-2019-1010178 | 1 Modx | 1 Fred | 2020-09-30 | 7.5 HIGH | 9.8 CRITICAL |
Fred MODX Revolution < 1.0.0-beta5 is affected by: Incorrect Access Control - CWE-648. The impact is: Remote Code Execution. The component is: assets/components/fred/web/elfinder/connector.php. The attack vector is: Uploading a PHP file or change data in the database. The fixed version is: https://github.com/modxcms/fred/commit/139cefac83b2ead90da23187d92739dec79d3ccd and https://github.com/modxcms/fred/commit/01f0a3d1ae7f3970639c2a0db1887beba0065246. | |||||
CVE-2018-8619 | 1 Microsoft | 9 Internet Explorer, Windows 10, Windows 7 and 6 more | 2020-09-28 | 7.6 HIGH | 7.5 HIGH |
A remote code execution vulnerability exists when the Internet Explorer VBScript execution policy does not properly restrict VBScript under specific conditions, aka "Internet Explorer Remote Code Execution Vulnerability." This affects Internet Explorer 9, Internet Explorer 11, Internet Explorer 10. | |||||
CVE-2020-24046 | 1 Titanhq | 1 Spamtitan | 2020-09-24 | 9.0 HIGH | 7.2 HIGH |
A sandbox escape issue was discovered in TitanHQ SpamTitan Gateway 7.07. It limits the admin user to a restricted shell, allowing execution of a small number of tools of the operating system. This restricted shell can be bypassed after changing the properties of the user admin in the operating system file /etc/passwd. This file cannot be accessed though the restricted shell, but it can be modified by abusing the Backup/Import Backup functionality of the web interface. An authenticated attacker would be able to obtain the file /var/tmp/admin.passwd after executing a Backup operation. This file can be manually modified to change the GUID of the user to 0 (root) and change the restricted shell to a normal shell /bin/sh. After the modification is done, the file can be recompressed to a .tar.bz file and imported again via the Import Backup functionality. The properties of the admin user will be overwritten and a root shell will be granted to the user upon the next successful login. | |||||
CVE-2020-0074 | 1 Google | 1 Android | 2020-09-23 | 7.2 HIGH | 7.8 HIGH |
In verifyIntentFiltersIfNeeded of PackageManagerService.java, there is a possible settings bypass allowing an app to become the default handler for arbitrary domains. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-8.0 Android-8.1 Android-9 Android-10Android ID: A-146204120 |