CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-40984 1 Yokogawa 2 Wtviewere 761941, Wtviewerefree 2022-10-25 N/A 9.8 CRITICAL
Stack-based buffer overflow in WTViewerE series WTViewerE 761941 from 1.31 to 1.61 and WTViewerEfree from 1.01 to 1.52 allows an attacker to cause the product to crash by processing a long file name.
CVE-2022-33939 1 Yokogawa 14 Centum Cs 3000 Cp31, Centum Cs 3000 Cp31 Firmware, Centum Cs 3000 Cp33 and 11 more 2022-08-17 N/A 7.5 HIGH
CENTUM VP / CS 3000 controller FCS (CP31, CP33, CP345, CP401, and CP451) contains an issue in processing communication packets, which may lead to resource consumption. If this vulnerability is exploited, an attacker may cause a denial of service (DoS) condition in ADL communication by sending a specially crafted packet to the affected product.
CVE-2022-30707 1 Yokogawa 11 B\/m9000 Vp, B\/m9000cs, Centum Cs 3000 and 8 more 2022-07-14 5.4 MEDIUM 8.8 HIGH
Violation of secure design principles exists in the communication of CAMS for HIS. Affected products and versions are CENTUM series where LHS4800 is installed (CENTUM CS 3000 and CENTUM CS 3000 Small R3.08.10 to R3.09.00), CENTUM series where CAMS function is used (CENTUM VP, CENTUM VP Small, and CENTUM VP Basic R4.01.00 to R4.03.00), CENTUM series regardless of the use of CAMS function (CENTUM VP, CENTUM VP Small, and CENTUM VP Basic R5.01.00 to R5.04.20 and R6.01.00 to R6.09.00), Exaopc R3.72.00 to R3.80.00 (only if NTPF100-S6 'For CENTUM VP Support CAMS for HIS' is installed), B/M9000 CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01). If an adjacent attacker successfully compromises a computer using CAMS for HIS software, they can use credentials from the compromised machine to access data from another machine using CAMS for HIS software. This can lead to a disabling of CAMS for HIS software functions on any affected machines, or information disclosure/alteration.
CVE-2022-32284 1 Yokogawa 2 Aw810d, Aw810d Firmware 2022-07-11 7.8 HIGH 7.5 HIGH
Use of insufficiently random values vulnerability exists in Vnet/IP communication module VI461 of YOKOGAWA Wide Area Communication Router (WAC Router) AW810D, which may allow a remote attacker to cause denial-of-service (DoS) condition by sending a specially crafted packet.
CVE-2022-29519 1 Yokogawa 4 Stardom Fcj, Stardom Fcj Firmware, Stardom Fcn and 1 more 2022-07-08 7.9 HIGH 7.5 HIGH
Cleartext transmission of sensitive information vulnerability exists in STARDOM FCN Controller and FCJ Controller R1.01 to R4.31, which may allow an adjacent attacker to login the affected products and alter device configuration settings or tamper with device firmware.
CVE-2022-30997 1 Yokogawa 4 Stardom Fcj, Stardom Fcj Firmware, Stardom Fcn and 1 more 2022-07-07 9.0 HIGH 7.2 HIGH
Use of hard-coded credentials vulnerability exists in STARDOM FCN Controller and FCJ Controller R4.10 to R4.31, which may allow an attacker with an administrative privilege to read/change configuration settings or update the controller with tampered firmware.
CVE-2022-26034 1 Yokogawa 2 B\/m9000 Vp, Centum Vp 2022-04-22 5.8 MEDIUM 9.1 CRITICAL
Improper authentication vulnerability in the communication protocol provided by AD (Automation Design) server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP Small R6.01.10 to R6.09.00, CENTUM VP Basic R6.01.10 to R6.09.00, and B/M9000 VP R8.01.01 to R8.03.01 allows an attacker to use the functions provided by AD server. This may lead to leakage or tampering of data managed by AD server.
CVE-2022-27188 1 Yokogawa 2 B\/m9000 Vp, Centum Vp 2022-04-22 4.4 MEDIUM 7.8 HIGH
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute an arbitrary OS command by altering a file generated using Graphic Builder.
CVE-2020-16232 1 Yokogawa 1 Widefield3 2022-03-28 7.5 HIGH 9.8 CRITICAL
In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.
CVE-2022-22148 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 6.9 MEDIUM 7.8 HIGH
'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-22151 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 4.9 MEDIUM 8.1 HIGH
CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-22145 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 4.9 MEDIUM 8.1 HIGH
CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-22141 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 4.4 MEDIUM 7.8 HIGH
'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-23401 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 3.7 LOW 7.8 HIGH
The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-22729 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 6.0 MEDIUM 8.8 HIGH
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-21808 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 6.0 MEDIUM 8.8 HIGH
Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-21194 1 Yokogawa 5 Centum Vp, Centum Vp Entry, Centum Vp Entry Firmware and 2 more 2022-03-18 6.8 MEDIUM 9.8 CRITICAL
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-21177 1 Yokogawa 9 Centum Cs 3000, Centum Cs 3000 Entry, Centum Cs 3000 Entry Firmware and 6 more 2022-03-18 4.9 MEDIUM 8.1 HIGH
There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
CVE-2022-23402 1 Yokogawa 5 Centum Vp, Centum Vp Entry, Centum Vp Entry Firmware and 2 more 2022-03-18 7.5 HIGH 9.8 CRITICAL
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
CVE-2019-5909 1 Yokogawa 4 B\/m 9000 Vp, Centum Vp, Prm and 1 more 2020-08-24 10.0 HIGH 9.8 CRITICAL
License Manager Service of YOKOGAWA products (CENTUM VP (R5.01.00 - R6.06.00), CENTUM VP Entry Class (R5.01.00 - R6.06.00), ProSafe-RS (R3.01.00 - R4.04.00), PRM (R4.01.00 - R4.02.00), B/M9000 VP(R7.01.01 - R8.02.03)) allows remote attackers to bypass access restriction to send malicious files to the PC where License Manager Service runs via unspecified vectors.