CVE-2023-23453 1 Sick 4 Fx0-gent00000, Fx0-gent00000 Firmware, Fx0-gent00010 and 1 more 2023-03-02 N/A 9.8 CRITICAL
Missing Authentication for Critical Function in SICK FX0-GENT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
CVE-2023-23452 1 Sick 4 Fx0-gpnt00000, Fx0-gpnt00000 Firmware, Fx0-gpnt00010 and 1 more 2023-03-02 N/A 9.8 CRITICAL
Missing Authentication for Critical Function in SICK FX0-GPNT v3 Firmware Version V3.04 and V3.05 allows an unprivileged remote attacker to achieve arbitrary remote code execution via maliciously crafted RK512 commands to the listener on TCP port 9000.
CVE-2021-32503 1 Sick 2 Ftmg, Ftmg Firmware 2023-01-24 4.0 MEDIUM 4.9 MEDIUM
Unauthenticated users can access sensitive web URLs through GET request, which should be restricted to maintenance users only. A malicious attacker could use this sensitive information’s to launch further attacks on the system.
CVE-2022-47377 1 Sick 2 Sim2000 Firmware, Sim2000st 2022-12-21 N/A 9.8 CRITICAL
Password recovery vulnerability in SICK SIM2000ST Partnumber 2086502 with firmware version <1.13.4 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.13.4 as soon as possible (available in SICK Support Portal).
CVE-2022-43989 1 Sick 4 Sim2000-2p04g10, Sim2000-2p04g10 Firmware, Sim2500-2p03g10 and 1 more 2022-12-16 N/A 7.3 HIGH
Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal).
CVE-2022-27582 1 Sick 14 Sim1000 Fx, Sim1000 Fx Firmware, Sim1004 and 11 more 2022-12-16 N/A 9.8 CRITICAL
Password recovery vulnerability in SICK SIM4000 (PPC) Partnumber 1078787 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.10.1 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM4000. A fix is planned but not yet scheduled.
CVE-2022-27584 1 Sick 2 Sim2000st, Sim2000st Firmware 2022-12-16 N/A 9.8 CRITICAL
Password recovery vulnerability in SICK SIM2000ST Partnumber 1080579 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The firmware versions <=1.7.0 allow to optionally disable device configuration over the network interfaces. Please make sure that you apply general security practices when operating the SIM2000ST. A fix is planned but not yet scheduled.
CVE-2022-43990 1 Sick 2 Sim1012-0p0g200, Sim1012-0p0g200 Firmware 2022-12-16 N/A 7.3 HIGH
Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal).
CVE-2022-27585 1 Sick 2 Sim1000 Fx, Sim1000 Fx Firmware 2022-12-16 N/A 9.8 CRITICAL
Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal).
CVE-2022-27586 1 Sick 2 Sim1004-0p0g311, Sim1004-0p0g311 Firmware 2022-12-16 N/A 9.8 CRITICAL
Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.0.0 as soon as possible (available in SICK Support Portal).
CVE-2022-46833 1 Sick 48 Rfu630-04100, Rfu630-04100 Firmware, Rfu630-04100s01 and 45 more 2022-12-15 N/A 6.5 MEDIUM
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU63x firmware version < v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
CVE-2022-46834 1 Sick 14 Rfu650-10100, Rfu650-10100 Firmware, Rfu650-10101 and 11 more 2022-12-15 N/A 6.5 MEDIUM
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU65x firmware version < v2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
CVE-2022-46832 1 Sick 42 Rfu620-10100, Rfu620-10100 Firmware, Rfu620-10101 and 39 more 2022-12-15 N/A 6.5 MEDIUM
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU62x firmware version < 2.21 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
CVE-2022-27581 1 Sick 24 Rfu610-10600, Rfu610-10600 Firmware, Rfu610-10601 and 21 more 2022-12-15 N/A 6.5 MEDIUM
Use of a Broken or Risky Cryptographic Algorithm in SICK RFU61x firmware version <v2.25 allows a low-privileged remote attacker to decrypt the encrypted data if the user requested weak cipher suites to be used for encryption via the SSH interface. The patch and installation procedure for the firmware update is available from the responsible SICK customer contact person.
CVE-2022-27583 1 Sick 4 Flx3-cpuc1, Flx3-cpuc1 Firmware, Flx3-cpuc2 and 1 more 2022-11-02 N/A 9.1 CRITICAL
A remote unprivileged attacker can interact with the configuration interface of a Flexi-Compact FLX3-CPUC1 or FLX3-CPUC2 running an affected firmware version to potentially impact the availability of the FlexiCompact.
CVE-2022-27579 1 Sick 1 Flexi Soft Designer 2022-07-27 N/A 7.8 HIGH
A deserialization vulnerability in a .NET framework class used and not properly checked by Flexi Soft Designer in all versions up to and including 1.9.4 SP1 allows an attacker to craft malicious project files. Opening/importing such a malicious project file would execute arbitrary code with the privileges of the current user when opened or imported by the Flexi Soft Designer. This compromises confidentiality integrity and availability. For the attack to succeed a user must manually open a malicious project file.
CVE-2022-27580 1 Sick 1 Safety Designer 2022-07-27 N/A 7.8 HIGH
A deserialization vulnerability in a .NET framework class used and not properly checked by Safety Designer all versions up to and including 1.11.0 allows an attacker to craft malicious project files. Opening/importing such a malicious project file would execute arbitrary code with the privileges of the current user when opened or imported by the Safety Designer. This compromises confidentiality integrity and availability. For the attack to succeed a user must manually open a malicious project file.
CVE-2021-32504 1 Sick 2 Ftmg, Ftmg Firmware 2022-07-27 N/A 5.3 MEDIUM
Unauthenticated users can access sensitive web URLs through GET request, which should be restricted to maintenance users only. A malicious attacker could use this sensitive information’s to launch further attacks on the system.
CVE-2021-32499 1 Sick 1 Sopas Engineering Tool 2022-07-12 5.0 MEDIUM 7.5 HIGH
SICK SOPAS ET before version 4.8.0 allows attackers to manipulate the command line arguments to pass in any value to the Emulator executable.
CVE-2022-27578 1 Sick 1 Overall Equipment Effectiveness 2022-04-19 4.6 MEDIUM 7.8 HIGH
An attacker can perform a privilege escalation through the SICK OEE if the application is installed in a directory where non authenticated or low privilege users can modify its content.