CVE-2017-16280 | 1 Insteon | 2 Hub, Hub Firmware | 2023-02-07 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d0181ec, the value for the `gate` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16303 | 1 Insteon | 2 Hub, Hub Firmware | 2023-02-07 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01addc, the value for the `cmd2` key is copied using `strcpy` to the buffer at `$sp+0x280`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16276 | 1 Insteon | 2 Hub, Hub Firmware | 2023-02-07 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_grp, at 0x9d0175f4, the value for the `gbt` key is copied using `strcpy` to the buffer at `$sp+0x280`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16275 | 1 Insteon | 2 Hub, Hub Firmware | 2023-02-07 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_grp, at 0x9d01758c, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16274 | 1 Insteon | 2 Hub, Hub Firmware | 2023-02-07 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd e_u, at 0x9d017364, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2018-3834 | 1 Insteon | 2 Hub, Hub Firmware | 2023-02-03 | 7.8 HIGH | 7.4 HIGH |
An exploitable permanent denial of service vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn't check the kind of firmware image that is going to be installed and thus allows for flashing any signed firmware into any MCU. Since the device contains different and incompatible MCUs, flashing one firmware to the wrong MCU will result in a permanent brick condition. To trigger this vulnerability, an attacker needs to impersonate the remote server "cache.insteon.com" and serve a signed firmware image. | |||||
CVE-2018-3833 | 1 Insteon | 2 Hub 2245-222, Hub 2245-222 Firmware | 2023-02-03 | 5.0 MEDIUM | 7.5 HIGH |
An exploitable firmware downgrade vulnerability exists in Insteon Hub running firmware version 1013. The firmware upgrade functionality, triggered via PubNub, retrieves signed firmware binaries using plain HTTP requests. The device doesn't check the firmware version that is going to be installed and thus allows for flashing older firmware images. To trigger this vulnerability, an attacker needs to impersonate the remote server 'cache.insteon.com' and serve any signed firmware image. | |||||
CVE-2018-3832 | 1 Insteon | 2 Hub 2245-222, Hub 2245-222 Firmware | 2023-02-03 | 8.5 HIGH | 9.0 CRITICAL |
An exploitable firmware update vulnerability exists in Insteon Hub running firmware version 1013. The HTTP server allows for uploading arbitrary MPFS binaries that could be modified to enable access to hidden resources which allow for uploading unsigned firmware images to the device. To trigger this vulnerability, an attacker can upload an MPFS binary via the '/mpfsupload' HTTP form and later on upload the firmware via a POST request to 'firmware.htm'. | |||||
CVE-2017-16348 | 1 Insteon | 2 Insteon Hub, Insteon Hub Firmware | 2023-01-27 | 7.8 HIGH | 7.5 HIGH |
An exploitable denial of service vulnerability exists in Insteon Hub running firmware version 1012. Leftover demo functionality allows for arbitrarily rebooting the device without authentication. An attacker can send a UDP packet to trigger this vulnerability. | |||||
CVE-2017-16301 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ad14, the value for the `flg` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16322 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_sonos, at 0x9d01e228, the value for the `c_group` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16259 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_auth, at 0x9d015430, the value for the `usr` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16293 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_schd, at 0x9d01a010, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x280`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16270 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d01679c, the value for the `s_sonos_cmd` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16302 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ad78, the value for the `cmd1` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16269 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d01672c, the value for the `s_speaker` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16268 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d0165c0, the value for the `id` key is copied using `strcpy` to the buffer at `$sp+0x270`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16267 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d016578, the value for the `val` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16294 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_schd, at 0x9d01a144, the value for the `on` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16264 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd l_b, at 0x9d015cfc, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. |