Filtered by vendor Cdatatec
Subscribe
Total
13 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-4257 | 1 Cdatatec | 1 C-data Web Management System | 2022-12-05 | N/A | 9.8 CRITICAL |
A vulnerability was found in C-DATA Web Management System. It has been rated as critical. This issue affects some unknown processing of the file cgi-bin/jumpto.php of the component GET Parameter Handler. The manipulation of the argument hostname leads to argument injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-214631. | |||||
CVE-2022-29337 | 1 Cdatatec | 2 Fd702xw-x-r430, Fd702xw-x-r430 Firmware | 2022-06-08 | 7.5 HIGH | 9.8 CRITICAL |
C-DATA FD702XW-X-R430 v2.1.13_X001 was discovered to contain a command injection vulnerability via the va_cmd parameter in formlanipv6. This vulnerability allows attackers to execute arbitrary commands via a crafted HTTP request. | |||||
CVE-2020-29056 | 2 Cdata, Cdatatec | 57 Fd1104 Firmware, 72408a, 72408a Firmware and 54 more | 2021-07-21 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. One can escape from a shell and acquire root privileges by leveraging the TFTP download configuration. | |||||
CVE-2020-29063 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-07-21 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. A custom encryption algorithm is used to store encrypted passwords. This algorithm will XOR the password with the hardcoded *j7a(L#yZ98sSd5HfSgGjMj8;Ss;d)(*&^#@$a2s0i3g value. | |||||
CVE-2020-29058 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-07-21 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can discover cleartext web-server credentials via certain /opt/lighttpd/web/cgi/ requests. | |||||
CVE-2020-29060 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account. | |||||
CVE-2020-29059 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware. | |||||
CVE-2020-29057 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. It allows remote attackers to cause a denial of service (reboot) by sending random bytes to the telnet server on port 23, aka a "shawarma" attack. | |||||
CVE-2020-29055 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 4.3 MEDIUM | 5.9 MEDIUM |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. By default, the appliance can be managed remotely only with HTTP, telnet, and SNMP. It doesn't support SSL/TLS for HTTP or SSH. An attacker can intercept passwords sent in cleartext and conduct man-in-the-middle attacks on the management of the appliance. | |||||
CVE-2020-29054 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can use "show system infor" to discover cleartext TELNET credentials. | |||||
CVE-2020-29062 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account. | |||||
CVE-2020-29061 | 1 Cdatatec | 56 72408a, 72408a Firmware, 9008a and 53 more | 2021-03-11 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account. | |||||
CVE-2018-20512 | 1 Cdatatec | 22 Epon Cpe-wifi Devices Firmware, Fd108bn, Fd111hz and 19 more | 2019-10-02 | 10.0 HIGH | 9.8 CRITICAL |
EPON CPE-WiFi devices 2.0.4-X000 are vulnerable to escalation of privileges by sending cooLogin=1, cooUser=admin, and timestamp=-1 cookies. |