Filtered by vendor Siemens
Subscribe
Total
1529 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2015-4174 | 1 Siemens | 1 Climatix Bacnet\/ip | 2016-12-07 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
CVE-2016-2846 | 1 Siemens | 2 Simatic S7 1200 Cpu, Simatic S7 Cpu 1200 Firmware | 2016-12-02 | 6.4 MEDIUM | 6.5 MEDIUM |
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors. | |||||
CVE-2016-3155 | 1 Siemens | 1 Apogee Insight | 2016-12-02 | 3.6 LOW | 3.4 LOW |
Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors. | |||||
CVE-2015-1358 | 1 Siemens | 1 Wincc | 2016-11-29 | 5.0 MEDIUM | N/A |
The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack. | |||||
CVE-2016-7090 | 1 Siemens | 4 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 1 more | 2016-11-28 | 4.3 MEDIUM | 4.0 MEDIUM |
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session. | |||||
CVE-2016-6486 | 1 Siemens | 1 Sinema Server | 2016-11-28 | 7.2 HIGH | 7.8 HIGH |
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors. | |||||
CVE-2016-6204 | 1 Siemens | 1 Sinema Remote Connect Server | 2016-11-28 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
CVE-2016-5743 | 1 Siemens | 5 Simatic Batch, Simatic Openpcs 7, Simatic Pcs 7 and 2 more | 2016-11-28 | 10.0 HIGH | 9.8 CRITICAL |
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets. | |||||
CVE-2016-5744 | 1 Siemens | 1 Simatic Wincc | 2016-11-28 | 5.0 MEDIUM | 7.5 HIGH |
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets. | |||||
CVE-2016-5848 | 1 Siemens | 1 Sicam Pas | 2016-11-28 | 1.7 LOW | 6.7 MEDIUM |
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges. | |||||
CVE-2016-5849 | 1 Siemens | 1 Sicam Pas | 2016-11-28 | 1.9 LOW | 2.5 LOW |
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. | |||||
CVE-2016-5874 | 1 Siemens | 1 Simatic Net Pc-software | 2016-11-28 | 5.0 MEDIUM | 7.5 HIGH |
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets. | |||||
CVE-2015-2823 | 1 Siemens | 6 Simatic Hmi Basic Panels Generation 1, Simatic Hmi Basic Panels Generation 2, Simatic Hmi Comfort Panels and 3 more | 2016-11-28 | 6.8 MEDIUM | N/A |
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. | |||||
CVE-2015-2822 | 1 Siemens | 1 Wincc | 2016-11-28 | 4.3 MEDIUM | N/A |
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. | |||||
CVE-2015-1601 | 1 Siemens | 1 Simatic Step 7 | 2016-11-28 | 6.8 MEDIUM | N/A |
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors. | |||||
CVE-2001-0411 | 1 Siemens | 1 Reliant Unix | 2016-10-17 | 5.0 MEDIUM | N/A |
Reliant Unix 5.44 and earlier allows remote attackers to cause a denial of service via an ICMP port unreachable packet, which causes Reliant to drop all connections to the source address of the packet. | |||||
CVE-2015-1594 | 1 Siemens | 5 Simatic Cfc, Simatic Prosave, Simatic Step 7 and 2 more | 2016-08-24 | 6.9 MEDIUM | N/A |
Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows local users to gain privileges via a Trojan horse application file. | |||||
CVE-2016-1488 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2016-03-04 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
CVE-2014-5233 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2015-11-13 | 1.9 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism. | |||||
CVE-2014-5231 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2015-11-13 | 2.1 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors. |