Filtered by vendor Siemens
Subscribe
Total
1529 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2003-1464 | 1 Siemens | 2 M45, S45 | 2017-07-28 | 7.8 HIGH | N/A |
Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name. | |||||
CVE-2016-9160 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2017-07-26 | 5.8 MEDIUM | 8.1 HIGH |
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions. | |||||
CVE-2004-2626 | 1 Siemens | 1 S55 | 2017-07-19 | 3.7 LOW | N/A |
GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message. | |||||
CVE-2017-2682 | 1 Siemens | 1 Ruggedcom Network Management Software | 2017-07-17 | 6.8 MEDIUM | 8.8 HIGH |
The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request. | |||||
CVE-2017-2683 | 1 Siemens | 1 Ruggedcom Network Management Software | 2017-07-17 | 4.3 MEDIUM | 8.2 HIGH |
A non-privileged user of the Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could perform a persistent Cross-Site Scripting (XSS) attack, potentially resulting in obtaining administrative permissions. | |||||
CVE-2017-2687 | 1 Siemens | 1 Ruggedcom Rox I | 2017-07-11 | 4.3 MEDIUM | 6.1 MEDIUM |
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link. | |||||
CVE-2017-6864 | 1 Siemens | 1 Ruggedcom Rox I | 2017-07-11 | 3.5 LOW | 5.4 MEDIUM |
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks. | |||||
CVE-2017-2688 | 1 Siemens | 1 Ruggedcom Rox I | 2017-07-11 | 6.8 MEDIUM | 8.8 HIGH |
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF. | |||||
CVE-2017-2686 | 1 Siemens | 1 Ruggedcom Rox I | 2017-07-11 | 4.0 MEDIUM | 6.5 MEDIUM |
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information. | |||||
CVE-2005-2424 | 1 Siemens | 1 Santis 50 | 2017-07-10 | 7.5 HIGH | N/A |
The management interface for Siemens SANTIS 50 running firmware 4.2.8.0, and possibly other products including Ericsson HN294dp and Dynalink RTA300W, allows remote attackers to access the Telnet port without authentication via certain packets to the web interface that cause the interface to freeze. | |||||
CVE-2016-9157 | 1 Siemens | 1 Sicam Pas | 2017-06-12 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP. | |||||
CVE-2016-9156 | 1 Siemens | 1 Sicam Pas | 2017-06-12 | 7.5 HIGH | 7.3 HIGH |
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP. | |||||
CVE-2016-7987 | 1 Siemens | 8 Eta2 Firmware, Eta4 Firmware, Sicam Ak and 5 more | 2017-03-14 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start might be required to recover the system, a Denial-of-Service Vulnerability. | |||||
CVE-2016-8566 | 1 Siemens | 1 Sicam Pas | 2017-02-28 | 4.6 MEDIUM | 7.8 HIGH |
An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database. | |||||
CVE-2016-8567 | 1 Siemens | 1 Sicam Pas | 2017-02-28 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP. | |||||
CVE-2016-9155 | 1 Siemens | 30 Ccid1445-dn18, Ccid1445-dn18 Firmware, Ccid1445-dn28 and 27 more | 2016-12-22 | 5.0 MEDIUM | 9.8 CRITICAL |
The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances. | |||||
CVE-2016-7960 | 1 Siemens | 1 Simatic Step 7 | 2016-12-22 | 1.9 LOW | 2.5 LOW |
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors. | |||||
CVE-2015-5698 | 1 Siemens | 2 Simatic S7 1200 Cpu, Simatic S7 1200 Cpu Firmware | 2016-12-21 | 7.5 HIGH | N/A |
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | |||||
CVE-2016-7959 | 1 Siemens | 1 Simatic Step 7 | 2016-12-21 | 1.9 LOW | 4.7 MEDIUM |
Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack. | |||||
CVE-2015-6675 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2016-12-21 | 4.3 MEDIUM | N/A |
Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic. |