Total
210374 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-4312 | 1 Rapidleech | 1 Rapidleech | 2023-01-23 | N/A | 6.1 MEDIUM |
** UNSUPPPORTED WHEN ASSIGNED **** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as problematic has been found in Th3-822 Rapidleech. This affects the function zip_go of the file classes/options/zip.php. The manipulation of the argument archive leads to cross site scripting. It is possible to initiate the attack remotely. The name of the patch is 885a87ea4ee5e14fa95801eca255604fb2e138c6. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-218295. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. | |||||
CVE-2017-16302 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_ex, at 0x9d01ad78, the value for the `cmd1` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2022-25026 | 1 Rocketsoftware | 1 Trufusion Enterprise | 2023-01-23 | N/A | 7.5 HIGH |
A Server-Side Request Forgery (SSRF) in Rocket TRUfusion Portal v7.9.2.1 allows remote attackers to gain access to sensitive resources on the internal network via a crafted HTTP request to /trufusionPortal/upDwModuleProxy. | |||||
CVE-2017-5242 | 1 Rapid7 | 1 Insightvm | 2023-01-23 | N/A | 7.7 HIGH |
Nexpose and InsightVM virtual appliances downloaded between April 5th, 2017 and May 3rd, 2017 contain identical SSH host keys. Normally, a unique SSH host key should be generated the first time a virtual appliance boots. | |||||
CVE-2021-23472 | 1 Bootstrap-table | 1 Bootstrap Table | 2023-01-23 | 4.3 MEDIUM | 6.1 MEDIUM |
This affects versions before 1.19.1 of package bootstrap-table. A type confusion vulnerability can lead to a bypass of input sanitization when the input provided to the escapeHTML function is an array (instead of a string) even if the escape attribute is set. | |||||
CVE-2017-16269 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d01672c, the value for the `s_speaker` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16268 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d0165c0, the value for the `id` key is copied using `strcpy` to the buffer at `$sp+0x270`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16267 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d016578, the value for the `val` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16294 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_schd, at 0x9d01a144, the value for the `on` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16264 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd l_b, at 0x9d015cfc, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16263 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd g_b, at 0x9d015a8c, the value for the `val` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16262 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd g_b, at 0x9d015864, the value for the `id` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16266 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d016530, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16265 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd l_bt, at 0x9d016104, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16258 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_sx, at 0x9d014f7c, the value for the `cmd4` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16257 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_sx, at 0x9d014f28, the value for the `cmd3` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16256 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd sn_sx, at 0x9d014ebc, the value for the `cmd2` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2017-16260 | 1 Insteon | 2 Hub, Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_auth, at 0x9d015478, the value for the `pwd` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | |||||
CVE-2022-46372 | 1 Alotceriot | 2 Ar7088h-a, Ar7088h-a Firmware | 2023-01-23 | N/A | 8.8 HIGH |
Alotcer - AR7088H-A firmware version 16.10.3 Command execution Improper validation of unspecified input field may allow Authenticated command execution. | |||||
CVE-2017-16295 | 1 Insteon | 2 Insteon Hub, Insteon Hub Firmware | 2023-01-23 | N/A | 9.9 CRITICAL |
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_schd, at 0x9d01a18c, the value for the `off` key is copied using `strcpy` to the buffer at `$sp+0x270`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. |