Total 71 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-1607 1 Juniper 44 Ex2300, Ex2300-c, Ex3400 and 41 more 2020-01-24 4.3 MEDIUM 6.1 MEDIUM
Insufficient Cross-Site Scripting (XSS) protection in J-Web may potentially allow a remote attacker to inject web script or HTML, hijack the target user's J-Web session and perform administrative actions on the Junos device as the targeted user. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90 on SRX Series; 14.1X53 versions prior to 14.1X53-D51 on EX and QFX Series; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.3 versions prior to 18.3R1-S6, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S2, 19.1R2.
CVE-2019-0054 1 Juniper 25 Csrx, Junos, Srx100 and 22 more 2019-10-17 5.8 MEDIUM 7.4 HIGH
An Improper Certificate Validation weakness in the SRX Series Application Identification (app-id) signature update client of Juniper Networks Junos OS allows an attacker to perform Man-in-the-Middle (MitM) attacks which may compromise the integrity and confidentiality of the device. This issue affects: Juniper Networks Junos OS 15.1X49 versions prior to 15.1X49-D120 on SRX Series devices. No other versions of Junos OS are affected.
CVE-2018-0025 1 Juniper 21 Junos, Srx100, Srx110 and 18 more 2019-10-09 4.3 MEDIUM 8.1 HIGH
When an SRX Series device is configured to use HTTP/HTTPS pass-through authentication services, a client sending authentication credentials in the initial HTTP/HTTPS session is at risk that these credentials may be captured during follow-on HTTP/HTTPS requests by a malicious actor through a man-in-the-middle attack or by authentic servers subverted by malicious actors. FTP, and Telnet pass-through authentication services are not affected. Affected releases are Juniper Networks SRX Series: 12.1X46 versions prior to 12.1X46-D67 on SRX Series; 12.3X48 versions prior to 12.3X48-D25 on SRX Series; 15.1X49 versions prior to 15.1X49-D35 on SRX Series.
CVE-2018-0024 1 Juniper 42 Ex2200, Ex2200-c, Ex2200\/vc and 39 more 2019-10-09 7.2 HIGH 7.8 HIGH
An Improper Privilege Management vulnerability in a shell session of Juniper Networks Junos OS allows an authenticated unprivileged attacker to gain full control of the system. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D45 on SRX Series; 12.3X48 versions prior to 12.3X48-D20 on SRX Series; 12.3 versions prior to 12.3R11 on EX Series; 14.1X53 versions prior to 14.1X53-D30 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100;; 15.1X49 versions prior to 15.1X49-D20 on SRX Series.
CVE-2018-0045 1 Juniper 23 Ex2300, Ex3400, Junos and 20 more 2019-10-09 5.8 MEDIUM 8.8 HIGH
Receipt of a specific Draft-Rosen MVPN control packet may cause the routing protocol daemon (RPD) process to crash and restart or may lead to remote code execution. By continuously sending the same specific Draft-Rosen MVPN control packet, an attacker can repeatedly crash the RPD process causing a prolonged denial of service. This issue may occur when the Junos OS device is configured for Draft-Rosen multicast virtual private network (MVPN). The VPN is multicast-enabled and configured to use Protocol Independent Multicast (PIM) protocol within the VPN. This issue can only be exploited from the PE device within the MPLS domain which is capable of forwarding IP multicast traffic in core. End-users connected to the CE device cannot cause this crash. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D70 on SRX Series; 15.1 versions prior to 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1F6; 15.1X49 versions prior to 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D59 on EX2300/EX3400 Series; 15.1X53 versions prior to 15.1X53-D67 on QFX10K Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX Series; 16.1 versions prior to 16.1R4-S9, 16.1R5-S4, 16.1R6-S3, 16.1R7; 16.2 versions prior to 16.2R1-S6, 16.2R2-S6, 16.2R3; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R2-S4, 17.2R3; 17.3 versions prior to 17.3R2-S2, 17.3R3; 17.4 versions prior to 17.4R1-S3, 17.4R2; 18.1 versions prior to 18.1R2. No other Juniper Networks products or platforms are affected by this issue.
CVE-2018-0020 1 Juniper 29 Ex2300, Ex3400, Junos and 26 more 2019-10-09 7.8 HIGH 7.5 HIGH
Junos OS may be impacted by the receipt of a malformed BGP UPDATE which can lead to a routing process daemon (rpd) crash and restart. Receipt of a repeated malformed BGP UPDATEs can result in an extended denial of service condition for the device. This malformed BGP UPDATE does not propagate to other BGP peers. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1F6-S10, 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D130 on SRX; 15.1X53 versions prior to 15.1X53-D66 on QFX10K; 15.1X53 versions prior to 15.1X53-D58 on EX2300/EX3400; 15.1X53 versions prior to 15.1X53-D233 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D471 on NFX; 16.1 versions prior to 16.1R3-S8, 16.1R4-S9, 16.1R5-S3, 16.1R6-S3, 16.1R7; 16.1X65 versions prior to 16.1X65-D47; 16.2 versions prior to 16.2R1-S6, 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R2-S3, 17.1R3; 17.2 versions prior to 17.2R1-S3, 17.2R2-S1, 17.2R3; 17.2X75 versions prior to 17.2X75-D70; 13.2 versions above and including 13.2R1. Versions prior to 13.2R1 are not affected. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue.
CVE-2018-0018 1 Juniper 21 Junos, Srx100, Srx110 and 18 more 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
On SRX Series devices during compilation of IDP policies, an attacker sending specially crafted packets may be able to bypass firewall rules, leading to information disclosure which an attacker may use to gain control of the target device or other internal devices, systems or services protected by the SRX Series device. This issue only applies to devices where IDP policies are applied to one or more rules. Customers not using IDP policies are not affected. Depending on if the IDP updates are automatic or not, as well as the interval between available updates, an attacker may have more or less success in performing reconnaissance or bypass attacks on the victim SRX Series device or protected devices. ScreenOS with IDP is not vulnerable to this issue. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D60 on SRX; 12.3X48 versions prior to 12.3X48-D35 on SRX; 15.1X49 versions prior to 15.1X49-D60 on SRX.
CVE-2018-0009 1 Juniper 21 Junos, Srx100, Srx110 and 18 more 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
On Juniper Networks SRX series devices, firewall rules configured to match custom application UUIDs starting with zeros can match all TCP traffic. Due to this issue, traffic that should have been blocked by other rules is permitted to flow through the device resulting in a firewall bypass condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71 on SRX series; 12.3X48 versions prior to 12.3X48-D55 on SRX series; 15.1X49 versions prior to 15.1X49-D100 on SRX series.
CVE-2018-0002 1 Juniper 31 Junos, Mx10, Mx104 and 28 more 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
On SRX Series and MX Series devices with a Service PIC with any ALG enabled, a crafted TCP/IP response packet processed through the device results in memory corruption leading to a flowd daemon crash. Sustained crafted response packets lead to repeated crashes of the flowd daemon which results in an extended Denial of Service condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D60 on SRX series; 12.3X48 versions prior to 12.3X48-D35 on SRX series; 14.1 versions prior to 14.1R9 on MX series; 14.2 versions prior to 14.2R8 on MX series; 15.1X49 versions prior to 15.1X49-D60 on SRX series; 15.1 versions prior to 15.1R5-S8, 15.1F6-S9, 15.1R6-S4, 15.1R7 on MX series; 16.1 versions prior to 16.1R6 on MX series; 16.2 versions prior to 16.2R3 on MX series; 17.1 versions prior to 17.1R2-S4, 17.1R3 on MX series. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-2341 1 Juniper 13 Acx5000, Ex4600, Junos and 10 more 2019-10-09 7.2 HIGH 8.8 HIGH
An insufficient authentication vulnerability on platforms where Junos OS instances are run in a virtualized environment, may allow unprivileged users on the Junos OS instance to gain access to the host operating environment, and thus escalate privileges. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D40 on QFX5110, QFX5200, QFX10002, QFX10008, QFX10016, EX4600 and NFX250; 15.1 prior to 15.1R5 on EX4600; 15.1X49 prior to 15.1X49-D70 on vSRX, SRX1500, SRX4100, SRX4200; 16.1 prior to 16.1R2 on EX4600, ACX5000 series. This issue does not affect vMX. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10620 1 Juniper 21 Junos, Srx100, Srx110 and 18 more 2019-10-09 5.8 MEDIUM 7.4 HIGH
Juniper Networks Junos OS on SRX series devices do not verify the HTTPS server certificate before downloading anti-virus updates. This may allow a man-in-the-middle attacker to inject bogus signatures to cause service disruptions or make the device not detect certain types of attacks. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D55; 15.1X49 prior to 15.1X49-D110;