CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-27430 | 1 Ge | 1 Ur Bootloader Binary | 2022-03-31 | 4.6 MEDIUM | 6.8 MEDIUM |
GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. | |||||
CVE-2020-25197 | 1 Ge | 6 Rt430, Rt430 Firmware, Rt431 and 3 more | 2022-03-28 | 9.0 HIGH | 8.8 HIGH |
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system. | |||||
CVE-2022-21798 | 1 Ge | 1 Cimplicity | 2022-03-08 | 7.5 HIGH | 9.8 CRITICAL |
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system. | |||||
CVE-2022-23921 | 1 Ge | 1 Proficy Cimplicitiy | 2022-03-08 | 3.7 LOW | 7.8 HIGH |
Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects. | |||||
CVE-2016-5787 | 1 Ge | 1 Cimplicity | 2022-02-03 | 4.6 MEDIUM | 6.3 MEDIUM |
General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors. | |||||
CVE-2016-9360 | 1 Ge | 3 Cimplicity, Historian, Ifix | 2022-02-03 | 4.4 MEDIUM | 6.7 MEDIUM |
An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session. | |||||
CVE-2020-16244 | 1 Ge | 1 Asset Performance Management Classic | 2021-11-22 | 4.0 MEDIUM | 7.2 HIGH |
GE Digital APM Classic, Versions 4.4 and prior. Salt is not used for hash calculation of passwords, making it possible to decrypt passwords. This design flaw, along with the IDOR vulnerability, puts the entire platform at high risk because an authenticated user can retrieve all user account data and then retrieve the actual passwords. | |||||
CVE-2021-31477 | 1 Ge | 2 Reason Rpv311 Firmware, Rpv311 | 2021-06-24 | 7.5 HIGH | 7.3 HIGH |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852. | |||||
CVE-2021-27454 | 1 Ge | 2 Reason Dr60, Reason Dr60 Firmware | 2021-03-30 | 4.6 MEDIUM | 7.8 HIGH |
The software performs an operation at a privilege level higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses on the Reason DR60 (all firmware versions prior to 02A04.1). | |||||
CVE-2021-27450 | 1 Ge | 2 Mu320e, Mu320e Firmware | 2021-03-29 | 4.6 MEDIUM | 7.8 HIGH |
SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1). | |||||
CVE-2016-2310 | 1 Ge | 8 Multilink Firmware, Multilink Ml1200, Multilink Ml1600 and 5 more | 2021-03-29 | 10.0 HIGH | 9.8 CRITICAL |
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface. | |||||
CVE-2021-27452 | 1 Ge | 2 Mu320e, Mu320e Firmware | 2021-03-29 | 10.0 HIGH | 9.8 CRITICAL |
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1). | |||||
CVE-2021-27448 | 1 Ge | 2 Mu320e, Mu320e Firmware | 2021-03-29 | 4.6 MEDIUM | 7.8 HIGH |
A miscommunication in the file system allows adversaries with access to the MU320E to escalate privileges on the MU320E (all firmware versions prior to v04A00.1). | |||||
CVE-2019-18255 | 1 Ge | 1 Ifix | 2021-02-24 | 2.1 LOW | 5.5 MEDIUM |
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation. | |||||
CVE-2019-18243 | 1 Ge | 1 Ifix | 2021-02-24 | 2.1 LOW | 5.5 MEDIUM |
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation. | |||||
CVE-2020-27265 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2021-01-21 | 7.5 HIGH | 9.8 CRITICAL |
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. | |||||
CVE-2020-27267 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2021-01-21 | 6.4 MEDIUM | 9.1 CRITICAL |
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | |||||
CVE-2020-27263 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2021-01-21 | 6.4 MEDIUM | 9.1 CRITICAL |
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | |||||
CVE-2020-16246 | 1 Ge | 4 S2020, S2020 Firmware, S2024 and 1 more | 2020-11-16 | 4.3 MEDIUM | 6.1 MEDIUM |
The affected Reason S20 Ethernet Switch is vulnerable to cross-site scripting (XSS), which may allow attackers to trick users into following a link or navigating to a page that posts a malicious JavaScript statement to the vulnerable site, causing the malicious JavaScript to be rendered by the site and executed by the victim client. | |||||
CVE-2019-6566 | 1 Ge | 1 Ge Communicator | 2020-10-16 | 7.2 HIGH | 7.8 HIGH |
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system. |