Filtered by vendor Siemens
Subscribe
Total
1529 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-37734 | 2 Arubanetworks, Siemens | 3 Aruba Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-07-12 | 4.0 MEDIUM | 6.5 MEDIUM |
A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.19 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 and below; Aruba Instant 8.8.x.x: 8.8.0.0 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability. | |||||
CVE-2020-27339 | 2 Insyde, Siemens | 33 Insydeh2o, Ruggedcom Apr1808, Ruggedcom Apr1808 Firmware and 30 more | 2022-07-12 | 7.2 HIGH | 6.7 MEDIUM |
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5). | |||||
CVE-2020-35683 | 2 Hcc-embedded, Siemens | 3 Nichestack, 7km9300-0ae02-0aa0, 7km9300-0ae02-0aa0 Firmware | 2022-07-12 | 5.0 MEDIUM | 7.5 HIGH |
An issue was discovered in HCC Nichestack 3.0. The code that parses ICMP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the ICMP checksum. When the IP payload size is set to be smaller than the size of the IP header, the ICMP checksum computation function may read out of bounds, causing a Denial-of-Service. | |||||
CVE-2020-26147 | 4 Arista, Debian, Linux and 1 more | 14 C-65, C-65 Firmware, C-75 and 11 more | 2022-07-12 | 3.2 LOW | 5.4 MEDIUM |
An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. | |||||
CVE-2019-6569 | 1 Siemens | 10 Scalance X-200, Scalance X-200 Firmware, Scalance X-300 and 7 more | 2022-07-12 | 6.4 MEDIUM | 9.1 CRITICAL |
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. | |||||
CVE-2021-40359 | 1 Siemens | 5 Simatic Batch, Simatic Net Pc, Simatic Route Control and 2 more | 2022-07-12 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. | |||||
CVE-2021-37185 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2022-07-12 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. | |||||
CVE-2021-37205 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2022-07-12 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. | |||||
CVE-2021-37204 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2022-07-12 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations. | |||||
CVE-2021-32803 | 3 Oracle, Siemens, Tar Project | 3 Graalvm, Sinec Infrastructure Network Services, Tar | 2022-07-02 | 5.8 MEDIUM | 8.1 HIGH |
The npm package "tar" (aka node-tar) before versions 6.1.2, 5.0.7, 4.4.15, and 3.2.3 has an arbitrary File Creation/Overwrite vulnerability via insufficient symlink protection. `node-tar` aims to guarantee that any file whose location would be modified by a symbolic link is not extracted. This is, in part, achieved by ensuring that extracted directories are not symlinks. Additionally, in order to prevent unnecessary `stat` calls to determine whether a given path is a directory, paths are cached when directories are created. This logic was insufficient when extracting tar files that contained both a directory and a symlink with the same name as the directory. This order of operations resulted in the directory being created and added to the `node-tar` directory cache. When a directory is present in the directory cache, subsequent calls to mkdir for that directory are skipped. However, this is also where `node-tar` checks for symlinks occur. By first creating a directory, and then replacing that directory with a symlink, it was thus possible to bypass `node-tar` symlink checks on directories, essentially allowing an untrusted tar file to symlink into an arbitrary location and subsequently extracting arbitrary files into that location, thus allowing arbitrary file creation and overwrite. This issue was addressed in releases 3.2.3, 4.4.15, 5.0.7 and 6.1.2. | |||||
CVE-2020-15800 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-01 | 9.3 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. | |||||
CVE-2021-37172 | 1 Siemens | 10 Cpu 1211c, Cpu 1212c, Cpu 1212fc and 7 more | 2022-07-01 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device. | |||||
CVE-2021-45034 | 1 Siemens | 8 Cp-8000 Master Module With I\/o -25\/\+70, Cp-8000 Master Module With I\/o -25\/\+70 Firmware, Cp-8000 Master Module With I\/o -40\/\+70 and 5 more | 2022-07-01 | 4.3 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links. | |||||
CVE-2021-37182 | 1 Siemens | 34 Scalance Xm408-4c, Scalance Xm408-4c Firmware, Scalance Xm408-4c L3 and 31 more | 2022-06-27 | 4.3 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device. | |||||
CVE-2022-30228 | 1 Siemens | 1 Sicam Gridedge Essential | 2022-06-24 | 4.3 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could be executed. | |||||
CVE-2022-27220 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-23 | 4.3 MEDIUM | 4.3 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 6220. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors. | |||||
CVE-2022-27219 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-23 | 4.3 MEDIUM | 4.3 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 443. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors. | |||||
CVE-2022-32252 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-23 | 9.3 HIGH | 7.8 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker. | |||||
CVE-2022-32254 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-23 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker. | |||||
CVE-2022-32256 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-23 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information. |