CVE-2021-37182

A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
References
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:1x230v:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:24v:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:2x230v:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:1x230v:*

Configuration 13 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:24v:*

Configuration 14 (hide)

AND
cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:2x230v:*

Configuration 15 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:1x230v:*

Configuration 17 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:24v:*

Configuration 18 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:2x230v:*

Configuration 19 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*

Configuration 20 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:1x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:1x230v:*

Configuration 21 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:24v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:24v:*

Configuration 22 (hide)

AND
cpe:2.3:o:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:2x230v:*
cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:2x230v:*

Configuration 23 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*

Configuration 24 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*

Configuration 25 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*

Configuration 26 (hide)

AND
cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*

Configuration 27 (hide)

AND
cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*

Configuration 28 (hide)

AND
cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*

Configuration 29 (hide)

AND
cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*

Information

Published : 2022-06-14 03:15

Updated : 2022-06-27 10:40


NVD link : CVE-2021-37182

Mitre link : CVE-2021-37182


JSON object : View

CWE
CWE-354

Improper Validation of Integrity Check Value

Advertisement

dedicated server usa

Products Affected

siemens

  • scalance_xr552-12m_firmware
  • scalance_xm408-4c_l3
  • scalance_xr528-6m_firmware
  • scalance_xm408-8c
  • scalance_xm416-4c_l3_firmware
  • scalance_xr528-6m_2hr2_firmware
  • scalance_xr528-6m_2hr2_l3_firmware
  • scalance_xm408-8c_firmware
  • scalance_xm408-4c_firmware
  • scalance_xr552-12m_2hr2_firmware
  • scalance_xm408-8c_l3
  • scalance_xm408-8c_l3_firmware
  • scalance_xr524-8c_l3
  • scalance_xr528-6m_2hr2
  • scalance_xr528-6m_l3_firmware
  • scalance_xr552-12m_2hr2_l3
  • scalance_xm408-4c_l3_firmware
  • scalance_xm416-4c_l3
  • scalance_xr526-8c_l3_firmware
  • scalance_xr528-6m_2hr2_l3
  • scalance_xm416-4c
  • scalance_xr524-8c
  • scalance_xr524-8c_l3_firmware
  • scalance_xr552-12m
  • scalance_xr526-8c
  • scalance_xr528-6m_l3
  • scalance_xr524-8c_firmware
  • scalance_xr552-12m_2hr2_l3_firmware
  • scalance_xr552-12m_2hr2
  • scalance_xr526-8c_l3
  • scalance_xm408-4c
  • scalance_xm416-4c_firmware
  • scalance_xr526-8c_firmware
  • scalance_xr528-6m