Total
210374 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2015-7921 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 6.4 MEDIUM | 9.1 CRITICAL |
The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials. | |||||
CVE-2021-43863 | 1 Nextcloud | 1 Nextcloud | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
The Nextcloud Android app is the Android client for Nextcloud, a self-hosted productivity platform. The Nextcloud Android app uses content providers to manage its data. Prior to version 3.18.1, the providers `FileContentProvider` and `DiskLruImageCacheFileProvider` have security issues (an SQL injection, and an insufficient permission control, respectively) that allow malicious apps in the same device to access Nextcloud's data bypassing the permission control system. Users should upgrade to version 3.18.1 to receive a patch. There are no known workarounds aside from upgrading. | |||||
CVE-2021-34870 | 1 Netgear | 1 Xr1000 | 2022-01-31 | 3.3 LOW | 6.5 MEDIUM |
This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of NETGEAR XR1000 1.0.0.52_1.0.38 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of SOAP messages. The issue results from a lack of authentication required for a privileged request. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-13325. | |||||
CVE-2021-22784 | 1 Schneider-electric | 1 C-bus Toolkit | 2022-01-31 | 3.5 LOW | 5.7 MEDIUM |
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system. | |||||
CVE-2021-22705 | 1 Schneider-electric | 9 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 6 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert | |||||
CVE-2021-22698 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |||||
CVE-2021-22697 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |||||
CVE-2020-7560 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Unity Pro | 2022-01-31 | 6.8 MEDIUM | 8.6 HIGH |
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. | |||||
CVE-2020-7544 | 1 Schneider-electric | 1 Operator Terminal Expert Runtime | 2022-01-31 | 7.2 HIGH | 7.8 HIGH |
A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert. | |||||
CVE-2020-7538 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | |||||
CVE-2020-28213 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus. | |||||
CVE-2020-28212 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus. | |||||
CVE-2020-28211 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. | |||||
CVE-2020-28209 | 2 Microsoft, Schneider-electric | 2 Windows, Enterprise Server Installer | 2022-01-31 | 4.4 MEDIUM | 7.0 HIGH |
A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location. | |||||
CVE-2020-28210 | 1 Schneider-electric | 1 Ecostruxure Building Operation | 2022-01-31 | 4.3 MEDIUM | 6.1 MEDIUM |
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser. | |||||
CVE-2020-10626 | 2 Fazecast, Schneider-electric | 2 Jserialcomm, Ecostruxure It Gateway | 2022-01-31 | 6.9 MEDIUM | 7.8 HIGH |
In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. | |||||
CVE-2019-6855 | 1 Schneider-electric | 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more | 2022-01-31 | 7.5 HIGH | 7.3 HIGH |
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. | |||||
CVE-2018-8088 | 3 Oracle, Qos, Redhat | 14 Goldengate Application Adapters, Goldengate Stream Analytics, Utilities Framework and 11 more | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
org.slf4j.ext.EventData in the slf4j-ext module in QOS.CH SLF4J before 1.8.0-beta2 allows remote attackers to bypass intended access restrictions via crafted data. EventData in the slf4j-ext module in QOS.CH SLF4J, has been fixed in SLF4J versions 1.7.26 later and in the 2.0.x series. | |||||
CVE-2016-2383 | 3 Canonical, Linux, Opensuse | 3 Ubuntu Linux, Linux Kernel, Leap | 2022-01-31 | 2.1 LOW | 5.5 MEDIUM |
The adjust_branches function in kernel/bpf/verifier.c in the Linux kernel before 4.5 does not consider the delta in the backward-jump case, which allows local users to obtain sensitive information from kernel memory by creating a packet filter and then loading crafted BPF instructions. | |||||
CVE-2019-3843 | 4 Canonical, Fedoraproject, Netapp and 1 more | 8 Ubuntu Linux, Fedora, Cn1610 and 5 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
It was discovered that a systemd service that uses DynamicUser property can create a SUID/SGID binary that would be allowed to run as the transient service UID/GID even after the service is terminated. A local attacker may use this flaw to access resources that will be owned by a potentially different service in the future, when the UID/GID will be recycled. |