CVE-2021-22766 | 1 Schneider-electric | 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
** UNSUPPORTED WHEN ASSIGNED ** A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet. | |||||
CVE-2021-22765 | 1 Schneider-electric | 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
** UNSUPPORTED WHEN ASSIGNED ** A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet. | |||||
CVE-2020-7500 | 1 Schneider-electric | 12 Mtn6260-0310, Mtn6260-0310 Firmware, Mtn6260-0315 and 9 more | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-89:Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause arbitrary code to be executed when a malicious command is entered. | |||||
CVE-2021-46086 | 1 Mindskip | 1 Xzs-mysql | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
xzs-mysql >= t3.4.0 is vulnerable to Insecure Permissions. The front end of this open source system is an online examination system. There is an unsafe vulnerability in the functional method of submitting examination papers. An attacker can use burpuite to modify parameters in the packet to destroy real data. | |||||
CVE-2020-7524 | 1 Schneider-electric | 2 Modicon M218, Modicon M218 Firmware | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal. | |||||
CVE-2020-7502 | 1 Schneider-electric | 2 Modicon M218, Modicon M218 Firmware | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-787: Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (Firmware version 4.3 and prior), which may cause a Denial of Service when specific TCP/IP crafted packets are sent to the Modicon M218 Logic Controller. | |||||
CVE-2021-46085 | 1 Oneblog Project | 1 Oneblog | 2022-01-31 | 4.0 MEDIUM | 6.5 MEDIUM |
OneBlog <= 2.2.8 is vulnerable to Insecure Permissions. Low level administrators can delete high-level administrators beyond their authority. | |||||
CVE-2020-7572 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser. | |||||
CVE-2020-7571 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 3.5 LOW | 5.4 MEDIUM |
A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users. | |||||
CVE-2020-7570 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 3.5 LOW | 5.4 MEDIUM |
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Stored) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and achieve a Cross-Site Scripting stored attack against other WebReport users. | |||||
CVE-2020-7569 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution. | |||||
CVE-2021-22777 | 1 Schneider-electric | 1 Sosafe Configurable | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. | |||||
CVE-2020-7501 | 1 Schneider-electric | 1 Vijeo Designer | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer. | |||||
CVE-2020-7498 | 1 Schneider-electric | 2 Os Loader, Unity Loader | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results. | |||||
CVE-2020-7490 | 1 Schneider-electric | 1 Vijeo Designer | 2022-01-31 | 6.9 MEDIUM | 7.8 HIGH |
A CWE-426: Untrusted Search Path vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior), which could cause arbitrary code execution on the system running Vijeo Basic when a malicious DLL library is loaded by the Product. | |||||
CVE-2018-7783 | 1 Schneider-electric | 1 Somachine Basic | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file. | |||||
CVE-2017-7965 | 1 Schneider-electric | 1 Somachine Hvac | 2022-01-31 | 4.6 MEDIUM | 7.3 HIGH |
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. | |||||
CVE-2016-2292 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 4.3 MEDIUM | 6.5 MEDIUM |
Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
CVE-2016-2291 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 4.3 MEDIUM | 6.5 MEDIUM |
Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors. | |||||
CVE-2016-2290 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 6.8 MEDIUM | 8.8 HIGH |
Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. |