Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Schneider-electric Subscribe
Total 675 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-22816 1 Schneider-electric 18 Scadapack 312e, Scadapack 312e Firmware, Scadapack 313e and 15 more 2022-02-03 7.8 HIGH 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior
CVE-2021-22809 1 Schneider-electric 1 Guicon 2022-02-02 4.3 MEDIUM 5.5 MEDIUM
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
CVE-2021-22808 1 Schneider-electric 1 Guicon 2022-02-02 6.8 MEDIUM 7.8 HIGH
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
CVE-2021-22807 1 Schneider-electric 1 Guicon 2022-02-02 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
CVE-2017-6026 1 Schneider-electric 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more 2022-02-02 6.4 MEDIUM 9.1 CRITICAL
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
CVE-2017-7689 1 Schneider-electric 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware 2022-02-01 10.0 HIGH 9.8 CRITICAL
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.
CVE-2018-7230 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 6.8 MEDIUM 8.8 HIGH
A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67.
CVE-2018-7229 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.5 HIGH 9.8 CRITICAL
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
CVE-2018-7231 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.5 HIGH 9.8 CRITICAL
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.
CVE-2018-7232 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.5 HIGH 9.8 CRITICAL
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.
CVE-2018-7233 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.5 HIGH 9.8 CRITICAL
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.
CVE-2018-7234 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.8 HIGH 7.5 HIGH
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.
CVE-2018-7235 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.8 HIGH 7.5 HIGH
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'
CVE-2018-7228 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.5 HIGH 9.8 CRITICAL
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.
CVE-2018-7227 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 5.0 MEDIUM 5.3 MEDIUM
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.
CVE-2018-7236 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 5.8 MEDIUM 8.1 HIGH
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
CVE-2018-7237 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 6.4 MEDIUM 9.1 CRITICAL
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'
CVE-2015-3962 1 Schneider-electric 1 Struxureware Building Expert Multi-purpose Management 2022-02-01 5.0 MEDIUM N/A
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.
CVE-2015-0982 1 Schneider-electric 1 Pelco Ds-nv 2022-02-01 7.5 HIGH N/A
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2018-7238 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2022-02-01 7.5 HIGH 9.8 CRITICAL
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.