Total
807 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-10622 | 1 Medtronic | 4 Mycarelink 24950 Patient Monitor, Mycarelink 24950 Patient Monitor Firmware, Mycarelink 24952 Patient Monitor and 1 more | 2019-10-09 | 1.9 LOW | 7.1 HIGH |
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest. | |||||
CVE-2018-0335 | 1 Cisco | 1 Prime Collaboration | 2019-10-09 | 2.1 LOW | 7.8 HIGH |
A vulnerability in the web portal authentication process of Cisco Prime Collaboration Provisioning could allow an unauthenticated, local attacker to view sensitive data. The vulnerability is due to improper logging of authentication data. An attacker could exploit this vulnerability by monitoring a specific World-Readable file for this authentication data (Cleartext Passwords). An exploit could allow the attacker to gain authentication information for other users. Cisco Bug IDs: CSCvd86602. | |||||
CVE-2017-9637 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2019-10-09 | 1.9 LOW | 4.1 MEDIUM |
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
CVE-2017-9654 | 1 Philips | 1 Dosewise | 2019-10-09 | 4.0 MEDIUM | 8.8 HIGH |
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N. | |||||
CVE-2017-7524 | 1 Tpm2-tools Project | 1 Tpm2.0-tools | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
tpm2-tools versions before 1.1.1 are vulnerable to a password leak due to transmitting password in plaintext from client to server when generating HMAC. | |||||
CVE-2017-7905 | 1 Ge | 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. | |||||
CVE-2017-7913 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext. | |||||
CVE-2017-7925 | 1 Dahuasecurity | 30 Ddh-hcvr4xxx, Dh-hcvr4xxx Firmware, Dh-hcvr5xxx and 27 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
A Password in Configuration File issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The password in configuration file vulnerability was identified, which could lead to a malicious user assuming the identity of a privileged user and gaining access to sensitive information. | |||||
CVE-2017-6709 | 1 Cisco | 1 Ultra Services Framework | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
A vulnerability in the AutoVNF tool for the Cisco Ultra Services Framework could allow an unauthenticated, remote attacker to access administrative credentials for Cisco Elastic Services Controller (ESC) and Cisco OpenStack deployments in an affected system. The vulnerability exists because the affected software logs administrative credentials in clear text for Cisco ESC and Cisco OpenStack deployment purposes. An attacker could exploit this vulnerability by accessing the AutoVNF URL for the location where the log files are stored and subsequently accessing the administrative credentials that are stored in clear text in those log files. This vulnerability affects all releases of the Cisco Ultra Services Framework prior to Releases 5.0.3 and 5.1. Cisco Bug IDs: CSCvc76659. | |||||
CVE-2017-2665 | 2 Mongodb, Redhat | 2 Mongodb, Storage Console | 2019-10-09 | 1.9 LOW | 7.0 HIGH |
The skyring-setup command creates random password for mongodb skyring database but it writes password in plain text to /etc/skyring/skyring.conf file which is owned by root but read by local user. Any local user who has access to system running skyring service will be able to get password in plain text. | |||||
CVE-2017-3192 | 1 D-link | 4 Dir-130, Dir-130 Firmware, Dir-330 and 1 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
D-Link DIR-130 firmware version 1.23 and DIR-330 firmware version 1.12 do not sufficiently protect administrator credentials. The tools_admin.asp page discloses the administrator password in base64 encoding in the returned web page. A remote attacker with access to this page (potentially through a authentication bypass such as CVE-2017-3191) may obtain administrator credentials for the device. | |||||
CVE-2017-1231 | 1 Ibm | 1 Bigfix Platform | 2019-10-09 | 2.1 LOW | 7.8 HIGH |
IBM BigFix Platform 9.5 - 9.5.9 stores user credentials in plain in clear text which can be read by a local user. IBM X-Force ID: 123910. | |||||
CVE-2017-1411 | 1 Ibm | 1 Security Identity Governance And Intelligence | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
IBM Security Identity Governance Virtual Appliance 5.2 through 5.2.3.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 127399. | |||||
CVE-2017-16731 | 1 Abb | 1 Ellipse | 2019-10-09 | 2.9 LOW | 8.8 HIGH |
An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (including Ellipse Select). A vulnerability exists in the authentication of Ellipse to LDAP/AD using the LDAP protocol. An attacker could exploit the vulnerability by sniffing local network traffic, allowing the discovery of authentication credentials. | |||||
CVE-2017-16714 | 1 Iceqube | 2 Thermal Management Center, Thermal Management Center Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
In Ice Qube Thermal Management Center versions prior to version 4.13, passwords are stored in plaintext in a file that is accessible without authentication. | |||||
CVE-2017-13998 | 1 Loytec | 2 Lvis-3me, Lvis-3me Firmware | 2019-10-09 | 6.0 MEDIUM | 7.5 HIGH |
An Insufficiently Protected Credentials issue was discovered in LOYTEC LVIS-3ME versions prior to 6.2.0. The application does not sufficiently protect sensitive information from unauthorized access. | |||||
CVE-2017-11510 | 1 Wanscam | 2 Hw0021, Hw0021 Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
An information leak exists in Wanscam's HW0021 network camera that allows an unauthenticated remote attacker to recover the administrator username and password via an ONVIF GetSnapshotUri request. | |||||
CVE-2017-1201 | 1 Ibm | 1 Bigfix Security Compliance Analytics | 2019-10-02 | 2.1 LOW | 7.8 HIGH |
IBM BigFix Compliance Analytics 1.9.79 (TEMA SUAv1 SCA SCM) stores user credentials in clear text which can be read by a local user. IBM X-Force ID: 123676. | |||||
CVE-2017-1000245 | 1 Jenkins | 1 Ssh | 2019-10-02 | 5.0 MEDIUM | 9.8 CRITICAL |
The SSH Plugin stores credentials which allow jobs to access remote servers via the SSH protocol. User passwords and passphrases for encrypted SSH keys are stored in plaintext in a configuration file. | |||||
CVE-2018-9280 | 1 Eaton | 2 9px Ups, 9px Ups Firmware | 2019-10-02 | 4.0 MEDIUM | 4.9 MEDIUM |
An issue was discovered on Eaton UPS 9PX 8000 SP devices. The appliance discloses the SNMP version 3 user's password. The web page displayed by the appliance contains the password in cleartext. Passwords of the read and write users could be retrieved by browsing the source code of the webpage. |