Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Schneider-electric Subscribe
Total 675 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-2329 1 Schneider-electric 1 Interactive Graphical Scada System 2023-02-08 N/A 9.8 CRITICAL
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)
CVE-2021-22786 1 Schneider-electric 82 Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware, Modicon M340 Bmxp342000 and 79 more 2023-02-08 N/A 7.5 HIGH
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
CVE-2022-32513 1 Schneider-electric 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more 2023-02-08 N/A 9.8 CRITICAL
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
CVE-2022-32514 1 Schneider-electric 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more 2023-02-08 N/A 9.8 CRITICAL
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
CVE-2022-24324 1 Schneider-electric 1 Interactive Graphical Scada System 2023-02-08 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)
CVE-2022-4062 1 Schneider-electric 1 Ecostruxure Power Commission 2023-02-08 N/A 3.3 LOW
A CWE-285: Improper Authorization vulnerability exists that could cause unauthorized access to certain software functions when an attacker gets access to localhost interface of the EcoStruxure Power Commission application. Affected Products: EcoStruxure Power Commission (Versions prior to V2.25)
CVE-2022-32748 1 Schneider-electric 1 Ecostruxure Cybersecurity Admin Expert 2023-02-08 N/A 8.1 HIGH
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
CVE-2022-32747 1 Schneider-electric 1 Ecostruxure Cybersecurity Admin Expert 2023-02-07 N/A 7.1 HIGH
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
CVE-2022-32521 1 Schneider-electric 1 Data Center Expert 2023-02-07 N/A 9.8 CRITICAL
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2023-22611 1 Schneider-electric 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 2023-02-07 N/A 7.5 HIGH
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
CVE-2023-22610 1 Schneider-electric 3 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020, Ecostruxure Geo Scada Expert 2021 2023-02-07 N/A 7.5 HIGH
A CWE-285: Improper Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
CVE-2022-32519 1 Schneider-electric 1 Data Center Expert 2023-02-07 N/A 9.8 CRITICAL
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32518 1 Schneider-electric 1 Data Center Expert 2023-02-07 N/A 9.8 CRITICAL
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32520 1 Schneider-electric 1 Data Center Expert 2023-02-07 N/A 9.8 CRITICAL
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32517 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2023-02-07 N/A 6.5 MEDIUM
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conext™ ComBox (All Versions)
CVE-2022-32515 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2023-02-07 N/A 9.8 CRITICAL
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
CVE-2022-32516 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2023-02-07 N/A 6.5 MEDIUM
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
CVE-2022-45789 1 Schneider-electric 72 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 69 more 2023-02-07 N/A 9.8 CRITICAL
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure™ Control Expert (All Versions), EcoStruxure™ Process Expert (Versions prior to V2020), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
CVE-2022-2988 1 Schneider-electric 2 Ecostruxure Machine Expert - Hvac, Somachine Hvac 2023-02-07 N/A 7.5 HIGH
A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)
CVE-2022-32512 1 Schneider-electric 1 Canbrass 2023-02-06 N/A 7.8 HIGH
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)