Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Moxa Subscribe
Total 245 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-32970 1 Moxa 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more 2022-04-11 7.8 HIGH 7.5 HIGH
Data can be copied without validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier, which may allow a remote attacker to cause denial-of-service conditions.
CVE-2021-32968 1 Moxa 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more 2022-04-11 5.0 MEDIUM 7.5 HIGH
Two buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O Series firmware version 2.2 or earlier may allow a remote attacker to cause a denial-of-service condition.
CVE-2021-32976 1 Moxa 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more 2022-04-11 7.5 HIGH 9.8 CRITICAL
Five buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to initiate a denial-of-service attack and execute arbitrary code.
CVE-2021-32974 1 Moxa 8 Nport Iaw5150a-12i\/o, Nport Iaw5150a-12i\/o Firmware, Nport Iaw5150a-6i\/o and 5 more 2022-04-11 10.0 HIGH 9.8 CRITICAL
Improper input validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to execute commands.
CVE-2021-46082 1 Moxa 12 Mgate 5101-pbm-mn, Mgate 5101-pbm-mn-t, Mgate 5101-pbm-mn-t Firmware and 9 more 2022-02-25 7.8 HIGH 7.5 HIGH
Moxa TN-5900 v3.1 series routers, MGate 5109 v2.2 series protocol gateways, and MGate 5101-PBM-MN v2.1 series protocol gateways were discovered to contain a memory leak which allows attackers to cause a Denial of Service (DoS) via crafted packets.
CVE-2021-46559 1 Moxa 2 Tn-5900, Tn-5900 Firmware 2022-02-01 5.0 MEDIUM 7.5 HIGH
The firmware on Moxa TN-5900 devices through 3.1 has a weak algorithm that allows an attacker to defeat an inspection mechanism for integrity protection.
CVE-2021-46560 1 Moxa 2 Tn-5900, Tn-5900 Firmware 2022-02-01 7.5 HIGH 9.8 CRITICAL
The firmware on Moxa TN-5900 devices through 3.1 allows command injection that could lead to device damage.
CVE-2021-4161 1 Moxa 6 Mgate Mb3180, Mgate Mb3180 Firmware, Mgate Mb3280 and 3 more 2022-01-07 5.0 MEDIUM 7.5 HIGH
The affected products contain vulnerable firmware, which could allow an attacker to sniff the traffic and decrypt login credential details. This could give an attacker admin rights through the HTTP web server.
CVE-2019-18238 1 Moxa 40 Iologik 2512, Iologik 2512-hspa, Iologik 2512-hspa-t and 37 more 2022-01-01 5.0 MEDIUM 7.5 HIGH
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account.
CVE-2019-6526 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2021-11-03 5.0 MEDIUM 9.8 CRITICAL
Moxa IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior use plaintext transmission of sensitive data, which may allow an attacker to capture sensitive data such as an administrative password.
CVE-2019-10963 1 Moxa 2 Edr-810, Edr-810 Firmware 2021-10-28 4.3 MEDIUM 4.3 MEDIUM
Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user.
CVE-2021-38458 1 Moxa 1 Mxview 2021-10-19 7.5 HIGH 9.8 CRITICAL
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
CVE-2021-38452 1 Moxa 1 Mxview 2021-10-19 6.4 MEDIUM 9.1 CRITICAL
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
CVE-2020-14511 1 Moxa 8 Edr-g902, Edr-g902-t, Edr-g902-t Firmware and 5 more 2021-09-23 7.5 HIGH 9.8 CRITICAL
Malicious operation of the crafted web browser cookie may cause a stack-based buffer overflow in the system web server on the EDR-G902 and EDR-G903 Series Routers (versions prior to 5.4).
CVE-2020-25192 1 Moxa 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware 2021-09-23 5.0 MEDIUM 5.3 MEDIUM
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization.
CVE-2020-25194 1 Moxa 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware 2021-09-23 6.5 MEDIUM 8.8 HIGH
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges.
CVE-2016-4514 1 Moxa 2 Pt-7728, Pt-7728 Firmware 2021-09-13 4.6 MEDIUM 7.7 HIGH
Moxa PT-7728 devices with software 3.4 build 15081113 allow remote authenticated users to change the configuration via vectors involving a local proxy.
CVE-2016-4503 1 Moxa 2 Device Server Web Console 5232-n, Device Server Web Console 5232-n Firmware 2021-09-13 5.0 MEDIUM 9.8 CRITICAL
Moxa Device Server Web Console 5232-N allows remote attackers to bypass authentication, and consequently modify settings and data, via vectors related to reading a cookie parameter containing a UserId value.
CVE-2021-39279 1 Moxa 24 Oncell G3470a-lte-eu, Oncell G3470a-lte-eu-t, Oncell G3470a-lte-eu-t Firmware and 21 more 2021-09-09 9.0 HIGH 8.8 HIGH
Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
CVE-2021-39278 1 Moxa 24 Oncell G3470a-lte-eu, Oncell G3470a-lte-eu-t, Oncell G3470a-lte-eu-t Firmware and 21 more 2021-09-09 4.3 MEDIUM 6.1 MEDIUM
Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.