Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Websense Subscribe
Filtered by product V-series Appliances
Total 11 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2015-2748 1 Websense 4 Triton Ap Data, Triton Ap Email, Triton Ap Web and 1 more 2018-10-09 5.0 MEDIUM N/A
Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorer_wse/, which allows remote attackers to obtain sensitive information via a direct request to a (1) Web Security incident report or the (2) Explorer configuration (websense.ini) file.
CVE-2015-2702 1 Websense 4 Triton Ap Data, Triton Ap Email, Triton Ap Web and 1 more 2018-10-09 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the Message Log in the Email Security Gateway in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via the sender address in an email.
CVE-2015-2703 1 Websense 2 Triton Ap Web, V-series Appliances 2018-10-09 4.3 MEDIUM N/A
Multiple cross-site scripting (XSS) vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the (1) ws-userip in the ws-encdata parameter to cve-bin/moreBlockInfo.cgi in the Data Security block page or (2) admin_msg parameter to configure/ssl_ui/eva-config/client-cert-import_wsoem.html in the Content Gateway, which is not properly handled in an error message.
CVE-2015-2746 1 Websense 2 Triton, V-series Appliances 2018-10-09 6.5 MEDIUM N/A
The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.
CVE-2015-2747 1 Websense 2 Triton, V-series Appliances 2018-10-09 4.3 MEDIUM N/A
Multiple cross-site scripting (XSS) vulnerabilities in the data loss prevention (DLP) incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted (1) email or (2) HTTP request, which triggers a DLP Policy.
CVE-2015-2773 1 Websense 1 V-series Appliances 2016-12-02 5.0 MEDIUM N/A
SVM in Websense TRITON V-Series appliances before 8.0.0 allows attackers to read arbitrary files via unspecified vectors.
CVE-2015-2768 1 Websense 2 Triton Ap Email, V-series Appliances 2016-12-02 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2015-2771 1 Websense 2 Triton Ap Email, V-series Appliances 2016-12-02 5.0 MEDIUM N/A
The Mail Server in Websense TRITON AP-EMAIL and V-Series appliances before 8.0.0 uses plaintext credentials, which allows remote attackers to obtain sensitive information via unspecified vectors.
CVE-2015-2772 1 Websense 1 V-series Appliances 2016-12-02 7.5 HIGH N/A
SVM in Websense TRITON V-Series appliances before 8.0.0 allows attackers to upload arbitrary files via unspecified vectors.
CVE-2014-9712 1 Websense 1 V-series Appliances 2016-06-23 4.0 MEDIUM N/A
Websense TRITON V-Series appliances before 7.8.3 Hotfix 03 and 7.8.4 before Hotfix 01 allow remote administrators to read arbitrary files and obtain passwords via a crafted path.
CVE-2015-2770 1 Websense 1 V-series Appliances 2015-03-30 6.8 MEDIUM N/A
Cross-site request forgery (CSRF) vulnerability in the command line page in Websense TRITON V-Series appliances before 8.0.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.