Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Siemens Subscribe
Filtered by product Simatic S7-1500 Software Controller
Total 16 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-38465 1 Siemens 89 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 86 more 2023-02-14 N/A 7.8 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.
CVE-2021-44694 1 Siemens 184 Simatic Et 200 Sp Open Controller Cpu 1515sp Pc, Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware, Simatic S7-1200 Cpu 1211c and 181 more 2023-02-06 N/A 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511T-1 PN, SIMATIC S7-1500 CPU 1511TF-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512SP F-1 PN, SIMATIC S7-1500 CPU 1512SP-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513R-1 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515R-2 PN, SIMATIC S7-1500 CPU 1515T-2 PN, SIMATIC S7-1500 CPU 1515TF-2 PN, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516T-3 PN/DP, SIMATIC S7-1500 CPU 1516TF-3 PN/DP, SIMATIC S7-1500 CPU 1517-3 PN/DP, SIMATIC S7-1500 CPU 1517F-3 PN/DP, SIMATIC S7-1500 CPU 1517H-3 PN, SIMATIC S7-1500 CPU 1517T-3 PN/DP, SIMATIC S7-1500 CPU 1517TF-3 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518-4F PN/DP, SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518HF-4 PN, SIMATIC S7-1500 CPU 1518T-4 PN/DP, SIMATIC S7-1500 CPU 1518TF-4 PN/DP, SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK, SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK, SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN, SIMATIC S7-1500 Software Controller, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN, SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN RAIL, SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL, SIPLUS S7-1500 CPU 1515R-2 PN, SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1517H-3 PN, SIPLUS S7-1500 CPU 1518-4 PN/DP, SIPLUS S7-1500 CPU 1518-4 PN/DP MFP, SIPLUS S7-1500 CPU 1518F-4 PN/DP, SIPLUS S7-1500 CPU 1518HF-4 PN, SIPLUS TIM 1531 IRC, TIM 1531 IRC. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
CVE-2021-44693 1 Siemens 192 Simatic Et 200 Sp Open Controller Cpu 1515sp Pc, Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware, Simatic S7-1200 Cpu 1211c and 189 more 2023-01-10 N/A 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511T-1 PN, SIMATIC S7-1500 CPU 1511TF-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512SP F-1 PN, SIMATIC S7-1500 CPU 1512SP-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513R-1 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515R-2 PN, SIMATIC S7-1500 CPU 1515T-2 PN, SIMATIC S7-1500 CPU 1515TF-2 PN, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516T-3 PN/DP, SIMATIC S7-1500 CPU 1516TF-3 PN/DP, SIMATIC S7-1500 CPU 1517-3 PN/DP, SIMATIC S7-1500 CPU 1517F-3 PN/DP, SIMATIC S7-1500 CPU 1517H-3 PN, SIMATIC S7-1500 CPU 1517T-3 PN/DP, SIMATIC S7-1500 CPU 1517TF-3 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518-4F PN/DP, SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518HF-4 PN, SIMATIC S7-1500 CPU 1518T-4 PN/DP, SIMATIC S7-1500 CPU 1518TF-4 PN/DP, SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK, SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK, SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN, SIMATIC S7-1500 Software Controller, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN, SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN RAIL, SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL, SIPLUS S7-1500 CPU 1515R-2 PN, SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1517H-3 PN, SIPLUS S7-1500 CPU 1518-4 PN/DP, SIPLUS S7-1500 CPU 1518-4 PN/DP MFP, SIPLUS S7-1500 CPU 1518F-4 PN/DP, SIPLUS S7-1500 CPU 1518HF-4 PN, SIPLUS TIM 1531 IRC, TIM 1531 IRC. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
CVE-2019-6568 1 Siemens 100 Cp1604, Cp1604 Firmware, Cp1616 and 97 more 2023-01-10 5.0 MEDIUM 7.5 HIGH
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CVE-2022-30694 1 Siemens 223 6ag1151-8ab01-7ab0, 6ag1151-8ab01-7ab0 Firmware, 6ag1151-8fb01-2ab0 and 220 more 2023-01-10 N/A 3.5 LOW
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
CVE-2021-44695 1 Siemens 192 Simatic Et 200 Sp Open Controller Cpu 1515sp Pc, Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware, Simatic S7-1200 Cpu 1211c and 189 more 2023-01-10 N/A 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511T-1 PN, SIMATIC S7-1500 CPU 1511TF-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512SP F-1 PN, SIMATIC S7-1500 CPU 1512SP-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513R-1 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515R-2 PN, SIMATIC S7-1500 CPU 1515T-2 PN, SIMATIC S7-1500 CPU 1515TF-2 PN, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516T-3 PN/DP, SIMATIC S7-1500 CPU 1516TF-3 PN/DP, SIMATIC S7-1500 CPU 1517-3 PN/DP, SIMATIC S7-1500 CPU 1517F-3 PN/DP, SIMATIC S7-1500 CPU 1517H-3 PN, SIMATIC S7-1500 CPU 1517T-3 PN/DP, SIMATIC S7-1500 CPU 1517TF-3 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518-4F PN/DP, SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518HF-4 PN, SIMATIC S7-1500 CPU 1518T-4 PN/DP, SIMATIC S7-1500 CPU 1518TF-4 PN/DP, SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK, SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK, SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN, SIMATIC S7-1500 Software Controller, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN, SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN RAIL, SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL, SIPLUS S7-1500 CPU 1515R-2 PN, SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1517H-3 PN, SIPLUS S7-1500 CPU 1518-4 PN/DP, SIPLUS S7-1500 CPU 1518-4 PN/DP MFP, SIPLUS S7-1500 CPU 1518F-4 PN/DP, SIPLUS S7-1500 CPU 1518HF-4 PN, SIPLUS TIM 1531 IRC, TIM 1531 IRC. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
CVE-2021-40365 1 Siemens 192 Simatic Et 200 Sp Open Controller Cpu 1515sp Pc, Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware, Simatic S7-1200 Cpu 1211c and 189 more 2023-01-10 N/A 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU 1510SP F-1 PN, SIMATIC S7-1500 CPU 1510SP-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511C-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511F-1 PN, SIMATIC S7-1500 CPU 1511T-1 PN, SIMATIC S7-1500 CPU 1511TF-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512C-1 PN, SIMATIC S7-1500 CPU 1512SP F-1 PN, SIMATIC S7-1500 CPU 1512SP-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513F-1 PN, SIMATIC S7-1500 CPU 1513R-1 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515F-2 PN, SIMATIC S7-1500 CPU 1515R-2 PN, SIMATIC S7-1500 CPU 1515T-2 PN, SIMATIC S7-1500 CPU 1515TF-2 PN, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516F-3 PN/DP, SIMATIC S7-1500 CPU 1516T-3 PN/DP, SIMATIC S7-1500 CPU 1516TF-3 PN/DP, SIMATIC S7-1500 CPU 1517-3 PN/DP, SIMATIC S7-1500 CPU 1517F-3 PN/DP, SIMATIC S7-1500 CPU 1517H-3 PN, SIMATIC S7-1500 CPU 1517T-3 PN/DP, SIMATIC S7-1500 CPU 1517TF-3 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP, SIMATIC S7-1500 CPU 1518-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518-4F PN/DP, SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP, SIMATIC S7-1500 CPU 1518HF-4 PN, SIMATIC S7-1500 CPU 1518T-4 PN/DP, SIMATIC S7-1500 CPU 1518TF-4 PN/DP, SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK, SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK, SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN, SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN, SIMATIC S7-1500 Software Controller, SIMATIC S7-PLCSIM Advanced, SIPLUS ET 200SP CPU 1510SP F-1 PN, SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1510SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS ET 200SP CPU 1512SP-1 PN RAIL, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511-1 PN TX RAIL, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1511F-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1513F-1 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN, SIPLUS S7-1500 CPU 1515F-2 PN RAIL, SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL, SIPLUS S7-1500 CPU 1515R-2 PN, SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP, SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL, SIPLUS S7-1500 CPU 1517H-3 PN, SIPLUS S7-1500 CPU 1518-4 PN/DP, SIPLUS S7-1500 CPU 1518-4 PN/DP MFP, SIPLUS S7-1500 CPU 1518F-4 PN/DP, SIPLUS S7-1500 CPU 1518HF-4 PN, SIPLUS TIM 1531 IRC, TIM 1531 IRC. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device.
CVE-2019-6575 1 Siemens 43 Opc Unified Architecture, Simatic Cp443-1 Opc Ua, Simatic Cp443-1 Opc Ua Firmware and 40 more 2022-10-06 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
CVE-2019-10943 1 Siemens 22 Simatic Et 200sp Open Controller Cpu 1515sp Pc, Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware and 19 more 2022-08-10 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
CVE-2021-37204 1 Siemens 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more 2022-07-12 7.1 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CVE-2021-37185 1 Siemens 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more 2022-07-12 7.1 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CVE-2021-37205 1 Siemens 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more 2022-07-12 7.1 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CVE-2017-2681 1 Siemens 155 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 Pn Io and 152 more 2022-04-12 6.1 MEDIUM 6.5 MEDIUM
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices.
CVE-2017-2680 1 Siemens 183 S110 Pn, Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware and 180 more 2022-04-12 6.1 MEDIUM 6.5 MEDIUM
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
CVE-2020-28397 1 Siemens 111 Cpu1510sp F-1, Cpu1510sp F-1 Firmware, Cpu 1211c and 108 more 2021-12-10 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
CVE-2020-15796 1 Siemens 4 Simatic Et 200sp Open Controller, Simatic Et 200sp Open Controller Firmware, Simatic S7-1500 Software Controller and 1 more 2020-12-17 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request.