Total
3 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-23449 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2022-04-19 | 6.9 MEDIUM | 7.3 HIGH |
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path. | |||||
CVE-2022-23450 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2022-04-19 | 10.0 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges. | |||||
CVE-2022-23448 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2022-04-19 | 7.2 HIGH | 7.8 HIGH |
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges. |