Filtered by vendor Siemens
Subscribe
Filtered by product Simatic Drive Controller Cpu 1507d Tf
Subscribe
Total
6 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-38465 | 1 Siemens | 89 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 86 more | 2023-02-14 | N/A | 7.8 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. | |||||
CVE-2022-38773 | 1 Siemens | 140 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 137 more | 2023-01-13 | N/A | 6.8 MEDIUM |
Affected devices do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot image of the device and execute arbitrary code. | |||||
CVE-2022-30694 | 1 Siemens | 223 6ag1151-8ab01-7ab0, 6ag1151-8ab01-7ab0 Firmware, 6ag1151-8fb01-2ab0 and 220 more | 2023-01-10 | N/A | 3.5 LOW |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V3.0.1), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIMATIC PC Station (All versions >= V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.6.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.0.1), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.19), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.19), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-PLCSIM Advanced (All versions < V5.0), SIMATIC WinCC Runtime Advanced (All versions), SINUMERIK ONE (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.19), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.19), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.19), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.19), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.19). The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. | |||||
CVE-2021-37185 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2022-07-12 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. | |||||
CVE-2021-37205 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2022-07-12 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. | |||||
CVE-2021-37204 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2022-07-12 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions >= V2.2). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations. |