Total
6 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2016-8359 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 4.3 MEDIUM | 6.1 MEDIUM |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING). | |||||
CVE-2016-8372 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 4.3 MEDIUM | 8.1 HIGH |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure. | |||||
CVE-2016-8379 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 4.3 MEDIUM | 8.1 HIGH |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords. | |||||
CVE-2016-8350 | 1 Moxa | 19 Iologik E1200 Series Firmware, Iologik E1210, Iologik E1211 and 16 more | 2021-05-19 | 6.8 MEDIUM | 6.3 MEDIUM |
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY). | |||||
CVE-2016-2282 | 1 Moxa | 16 Ioadmin Firmware, Iologik E2210, Iologik E2210-t and 13 more | 2021-05-19 | 5.0 MEDIUM | 5.3 MEDIUM |
Moxa ioLogik E2200 devices before 3.12 and ioAdmin Configuration Utility before 3.18 do not properly encrypt credentials, which makes it easier for remote attackers to obtain the associated cleartext via unspecified vectors. | |||||
CVE-2016-2283 | 1 Moxa | 16 Ioadmin Firmware, Iologik E2210, Iologik E2210-t and 13 more | 2021-05-19 | 5.0 MEDIUM | 5.3 MEDIUM |
Moxa ioLogik E2200 devices before 3.12 and ioAdmin Configuration Utility before 3.18 do not properly encrypt data, which makes it easier for remote attackers to obtain the associated cleartext via unspecified vectors. |