Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Eq-3 Subscribe
Filtered by product Homematic Central Control Unit Ccu2
Total 5 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-7296 1 Eq-3 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware 2019-10-02 5.0 MEDIUM 5.3 MEDIUM
Directory Traversal / Arbitrary File Read in User.getLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to read the first line of an arbitrary file on the CCU2's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
CVE-2018-7297 1 Eq-3 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware 2019-10-02 10.0 HIGH 9.8 CRITICAL
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
CVE-2018-7298 1 Eq-3 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware 2019-10-02 9.3 HIGH 8.1 HIGH
In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise.
CVE-2018-7299 1 Eq-3 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware 2019-10-02 5.2 MEDIUM 8.0 HIGH
Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device.
CVE-2018-7301 1 Eq-3 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware 2018-03-18 7.5 HIGH 9.8 CRITICAL
eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.