Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Linksys Subscribe
Filtered by product E2500
Total 3 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-3955 1 Linksys 4 E1200, E1200 Firmware, E2500 and 1 more 2022-04-19 9.0 HIGH 7.2 HIGH
An exploitable operating system command injection exists in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04). Specially crafted entries to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker can send an authenticated HTTP request to trigger this vulnerability. Data entered into the 'Domain Name' input field through the web portal is submitted to apply.cgi as the value to the 'wan_domain' POST parameter. The wan_domain data goes through the nvram_set process described above. When the 'preinit' binary receives the SIGHUP signal it enters a code path that calls a function named 'set_host_domain_name' from its libshared.so shared object.
CVE-2018-3954 1 Linksys 4 E1200, E1200 Firmware, E2500 and 1 more 2022-04-19 9.0 HIGH 7.2 HIGH
Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAMData entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal it enters a code path that calls a function named 'set_host_domain_name' from its libshared.so shared object.
CVE-2018-3953 1 Linksys 4 E1200, E1200 Firmware, E2500 and 1 more 2022-04-19 9.0 HIGH 7.2 HIGH
Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAM. Data entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal, it enters a code path that continues until it reaches offset 0x0042B5C4 in the 'start_lltd' function. Within the 'start_lltd' function, a 'nvram_get' call is used to obtain the value of the user-controlled 'machine_name' NVRAM entry. This value is then entered directly into a command intended to write the host name to a file and subsequently executed.