Total
2 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-0289 | 1 Juniper | 229 Acx1000, Acx1100, Acx2000 and 226 more | 2021-07-28 | 2.9 LOW | 5.3 MEDIUM |
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved. | |||||
CVE-2021-0273 | 1 Juniper | 9 Acx5800, Ex9200, Junos and 6 more | 2021-05-04 | 5.0 MEDIUM | 5.3 MEDIUM |
An always-incorrect control flow implementation in the implicit filter terms of Juniper Networks Junos OS and Junos OS Evolved on ACX5800, EX9200 Series, MX10000 Series, MX240, MX480, MX960 devices with affected Trio line cards allows an attacker to exploit an interdependency in the PFE UCODE microcode of the Trio chipset with various line cards to cause packets destined to the devices interfaces to cause a Denial of Service (DoS) condition by looping the packet with an unreachable exit condition ('Infinite Loop'). To break this loop once it begins one side of the affected LT interfaces will need to be disabled. Once disabled, the condition will clear and the disabled LT interface can be reenabled. Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. This issue only affects LT-LT interfaces. Any other interfaces are not affected by this issue. This issue affects the following cards: MPCE Type 3 3D MPC4E 3D 32XGE MPC4E 3D 2CGE+8XGE EX9200 32x10G SFP EX9200-2C-8XS FPC Type 5-3D FPC Type 5-LSR EX9200 4x40G QSFP An Indicator of Compromise (IoC) can be seen by examining the traffic of the LT-LT interfaces for excessive traffic using the following command: monitor interface traffic Before loop impact: Interface: lt-2/0/0, Enabled, Link is Up Encapsulation: Logical-tunnel, Speed: 100000mbps Traffic statistics: Current delta Input bytes: 3759900268942 (1456 bps) [0] <---------- LT interface utilization is low Output bytes: 3759900344309 (1456 bps) [0] <---------- LT interface utilization is low After loop impact: Interface: lt-2/0/0, Enabled, Link is Up Encapsulation: Logical-tunnel, Speed: 100000mbps Traffic statistics: Current delta Input bytes: 3765160313129 (2158268368 bps) [5260044187] <---------- LT interface utilization is very high Output bytes: 3765160399522 (2158266440 bps) [5260055213] <---------- LT interface utilization is very high This issue affects: Juniper Networks Junos OS on ACX5800, EX9200 Series, MX10000 Series, MX240, MX480, MX960. Versions 15.1F6, 16.1R1, and later versions prior to 16.1R7-S8; 17.1 versions prior to 17.1R2-S12; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R3-S2; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3-S2; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S3, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. This issue does not affect the MX10001. This issue does not affect Juniper Networks Junos OS versions prior to 15.1F6, 16.1R1. Juniper Networks Junos OS Evolved on ACX5800, EX9200 Series, MX10000 Series, MX240, MX480, MX960 19.4 versions prior to 19.4R2-EVO. This issue does not affect the MX10001. |