CVE-2019-0043 | 1 Juniper | 47 Acx1000, Acx1100, Acx2000 and 44 more | 2021-10-28 | 5.0 MEDIUM | 7.5 HIGH |
In MPLS environments, receipt of a specific SNMP packet may cause the routing protocol daemon (RPD) process to crash and restart. By continuously sending a specially crafted SNMP packet, an attacker can repetitively crash the RPD process causing prolonged denial of service. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS : 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D75 on SRX Series; 14.1X53 versions prior to 14.1X53-D48 on EX/QFX series; 15.1 versions prior to 15.1R4-S9, 15.1R7-S2; 15.1F6 versions prior to 15.1F6-S11; 15.1X49 versions prior to 15.1X49-D141, 15.1X49-D144, 15.1X49-D150 on SRX Series; 15.1X53 versions prior to 15.1X53-D234 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10K Series; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX Series; 15.1X53 versions prior to 15.1X53-D590 on EX2300/EX3400 Series; 15.1X54 on ACX Series; 16.1 versions prior to 16.1R3-S10, 16.1R4-S11, 16.1R6-S5, 16.1R7; 16.1X65 versions prior to 16.1X65-D48; 16.2 versions prior to 16.2R2-S6; 17.1 versions prior to 17.1R2-S8, 17.1R3; 17.2 versions prior to 17.2R1-S7, 17.2R3; 17.2X75 versions prior to 17.2X75-D92, 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R3; 17.4 versions prior to 17.4R1-S4, 17.4R2; 18.1 versions prior to 18.1R1-S1, 18.1R2-S1, 18.1R3; 18.2X75 versions prior to 18.2X75-D10. | |||||
CVE-2021-0289 | 1 Juniper | 229 Acx1000, Acx1100, Acx2000 and 226 more | 2021-07-28 | 2.9 LOW | 5.3 MEDIUM |
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved. |