Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Total 210374 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-5161 1 Sielcosistemi 2 Winlog Lite, Winlog Pro 2017-03-15 9.3 HIGH 7.2 HIGH
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL.
CVE-2016-7553 1 Irssi 1 Buf.pl 2017-03-15 2.1 LOW 3.3 LOW
The buf.pl script before 2.20 in Irssi before 0.8.20 uses weak permissions for the scrollbuffer dump file created between upgrades, which might allow local users to obtain sensitive information from private chat conversations by reading the file.
CVE-2016-8232 1 Ibm 3 Advanced Management Module, Advanced Management Module Firmware, Bladecenter 2017-03-15 4.3 MEDIUM 6.1 MEDIUM
Document Object Model-(DOM) based cross-site scripting vulnerability in the Advanced Management Module (AMM) versions earlier than 66Z of Lenovo IBM BladeCenter HS22, HS22V, HS23, HS23E, HX5 allows an unauthenticated attacker with access to the AMM's IP address to send a crafted URL that could inject a malicious script to access a user's AMM data such as cookies or other session information.
CVE-2010-4314 2 Microsoft, Novell 4 Windows 7, Windows Vista, Windows Xp and 1 more 2017-03-15 9.3 HIGH 8.8 HIGH
Remote attackers can use the iPrint web-browser ActiveX plugin in Novell iPrint Client before 5.42 for Windows XP/Vista/Win7 to execute code by overflowing the "name" parameter.
CVE-2017-5675 1 Embedthis 1 Goahead 2017-03-15 9.0 HIGH 8.8 HIGH
A command-injection vulnerability exists in a web application on a custom-built GoAhead web server used on Foscam, Vstarcam, and multiple white-label IP camera models. The mail-sending form in the mail.htm page allows an attacker to inject a command into the receiver1 field in the form; it will be executed with root privileges.
CVE-2013-4659 2 Asus, Trendnet 4 Rt-ac66u, Rt-ac66u Firmware, Tew-812dru and 1 more 2017-03-15 10.0 HIGH 9.8 CRITICAL
Buffer overflow in Broadcom ACSD allows remote attackers to execute arbitrary code via a long string to TCP port 5916. This component is used on routers of multiple vendors including ASUS RT-AC66U and TRENDnet TEW-812DRU.
CVE-2016-8002 2017-03-15 N/A N/A
** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2016. Notes: none.
CVE-2016-10101 1 Hiteksoftware 1 Automize 2017-03-14 4.3 MEDIUM 8.1 HIGH
Information Disclosure can occur in Hitek Software's Automize 10.x and 11.x passManager.jsd. Users have the Read attribute, which allows an attacker to recover the encrypted password to access the Password Manager.
CVE-2016-1185 1 Cybozu 1 Kintone 2017-03-14 2.6 LOW 2.5 LOW
The Cybozu kintone mobile application 1.x before 1.0.6 for Android allows attackers to discover an authentication token via a crafted application.
CVE-2017-6427 1 Evostream 1 Media Server 2017-03-14 5.0 MEDIUM 7.5 HIGH
A Buffer Overflow was discovered in EvoStream Media Server 1.7.1. A crafted HTTP request with a malicious header will cause a crash. An example attack methodology may include a long message-body in a GET request.
CVE-2017-6506 1 Azure Dex 1 Data Expert Ultimate 2017-03-14 7.5 HIGH 9.8 CRITICAL
In Azure Data Expert Ultimate 2.2.16, the SMTP verification function suffers from a buffer overflow vulnerability, leading to remote code execution. The attack vector is a crafted SMTP daemon that sends a long 220 (aka "Service ready") string.
CVE-2017-6807 1 Uninett 1 Mod Auth Mellon 2017-03-14 4.3 MEDIUM 6.1 MEDIUM
mod_auth_mellon before 0.13.1 is vulnerable to a Cross-Site Session Transfer attack, where a user with access to one web site running on a server can copy their session cookie to a different web site on the same server to get access to that site.
CVE-2016-7987 1 Siemens 8 Eta2 Firmware, Eta4 Firmware, Sicam Ak and 5 more 2017-03-14 7.8 HIGH 7.5 HIGH
An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start might be required to recover the system, a Denial-of-Service Vulnerability.
CVE-2017-6466 1 F-secure 1 Software Updater 2017-03-14 9.3 HIGH 8.1 HIGH
F-Secure Software Updater 2.20, as distributed in several F-Secure products, downloads installation packages over plain http and does not perform file integrity validation after download. Man-in-the-middle attackers can replace the file with their own executable which will be executed under the SYSTEM account. Note that when Software Updater is configured to install updates automatically, it checks if the downloaded file is digitally signed by default, but does not check the author of the signature. When running in manual mode (default), no signature check is performed.
CVE-2017-6465 1 Ftpshell 1 Ftpshell Client 2017-03-14 7.5 HIGH 9.8 CRITICAL
Remote Code Execution was discovered in FTPShell Client 6.53. By default, the client sends a PWD command to the FTP server it is connecting to; however, it doesn't check the response's length, leading to a buffer overflow situation.
CVE-2017-5933 1 Citrix 1 Netscaler Application Delivery Controller Firmware 2017-03-14 4.3 MEDIUM 5.9 MEDIUM
Citrix NetScaler ADC and NetScaler Gateway 10.5 before Build 65.11, 11.0 before Build 69.12/69.123, and 11.1 before Build 51.21 randomly generates GCM nonces, which makes it marginally easier for remote attackers to obtain the GCM authentication key and spoof data by leveraging a reused nonce in a session and a "forbidden attack," a similar issue to CVE-2016-0270.
CVE-2016-5815 1 Schneider-electric 6 Ion5000, Ion7300, Ion7500 and 3 more 2017-03-14 7.5 HIGH 9.8 CRITICAL
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
CVE-2016-5782 1 Locusenergy 6 Lgate 100, Lgate 101, Lgate 120 and 3 more 2017-03-14 7.5 HIGH 8.6 HIGH
An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information that is sent in the POST request.
CVE-2014-3926 1 Lg Project 1 Lg 2017-03-14 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in lg.cgi in Cougar LG 1.9 allows remote attackers to inject arbitrary web script or HTML via the "addr" parameter.
CVE-2016-5805 1 Delta Electronics 3 Ispsoft, Pmsoft, Wplsoft 2017-03-14 6.8 MEDIUM 7.8 HIGH
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to2.10.10. There are multiple instances of heap-based buffer overflows that may allow malicious files to cause the execution of arbitrary code or a denial of service.