CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-25153 1 Moxa 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware 2020-12-23 5.0 MEDIUM 7.5 HIGH
The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords.
CVE-2020-25190 1 Moxa 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware 2020-12-23 5.0 MEDIUM 9.8 CRITICAL
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext.
CVE-2020-25198 1 Moxa 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware 2020-12-23 6.8 MEDIUM 8.8 HIGH
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user’s cookies.
CVE-2020-25196 1 Moxa 2 Nport Iaw5000a-i\/o, Nport Iaw5000a-i\/o Firmware 2020-12-23 5.0 MEDIUM 9.8 CRITICAL
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
CVE-2020-23639 1 Moxa 2 Vport 461, Vport 461 Firmware 2020-11-12 10.0 HIGH 9.8 CRITICAL
A command injection vulnerability exists in Moxa Inc VPort 461 Series Firmware Version 3.4 or lower that could allow a remote attacker to execute arbitrary commands in Moxa's VPort 461 Series Industrial Video Servers.
CVE-2019-6524 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2020-10-19 5.0 MEDIUM 9.8 CRITICAL
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
CVE-2019-6520 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2020-10-19 5.0 MEDIUM 7.5 HIGH
Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes.
CVE-2019-6518 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2020-10-19 5.0 MEDIUM 7.5 HIGH
Moxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device.
CVE-2019-6563 1 Moxa 8 Eds-405a, Eds-405a Firmware, Eds-408a and 5 more 2020-10-05 10.0 HIGH 9.8 CRITICAL
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
CVE-2018-18396 1 Moxa 1 Thingspro 2020-08-24 7.5 HIGH 9.8 CRITICAL
Remote Code Execution in Moxa ThingsPro IIoT Gateway and Device Management Software Solutions version 2.1.
CVE-2018-10699 1 Moxa 2 Awk-3121, Awk-3121 Firmware 2020-08-24 6.8 MEDIUM 8.8 HIGH
An issue was discovered on Moxa AWK-3121 1.14 devices. The Moxa AWK 3121 provides certfile upload functionality so that an administrator can upload a certificate file used for connecting to the wireless network. However, the same functionality allows an attacker to execute commands on the device. The POST parameter "iw_privatePass" is susceptible to this injection. By crafting a packet that contains shell metacharacters, it is possible for an attacker to execute the attack.
CVE-2018-11420 1 Moxa 4 Oncell G3150-hspa, Oncell G3150-hspa-t, Oncell G3150-hspa-t Firmware and 1 more 2020-08-24 7.5 HIGH 9.8 CRITICAL
There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.
CVE-2018-11421 1 Moxa 4 Oncell G3150-hspa, Oncell G3150-hspa-t, Oncell G3150-hspa-t Firmware and 1 more 2020-08-24 5.0 MEDIUM 9.8 CRITICAL
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.
CVE-2018-11422 1 Moxa 4 Oncell G3150-hspa, Oncell G3150-hspa-t, Oncell G3150-hspa-t Firmware and 1 more 2020-08-24 7.5 HIGH 9.8 CRITICAL
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands (including device reboot, configuration download or upload, or firmware upgrade) are accepted and executed by the device without authentication.
CVE-2018-11424 1 Moxa 8 Oncell G3470a-lte-eu, Oncell G3470a-lte-eu-t, Oncell G3470a-lte-eu-t Firmware and 5 more 2020-08-24 7.8 HIGH 7.5 HIGH
There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425.
CVE-2018-18395 1 Moxa 1 Thingspro 2020-08-24 10.0 HIGH 9.8 CRITICAL
Hidden Token Access in Moxa ThingsPro IIoT Gateway and Device Management Software Solutions version 2.1.
CVE-2020-6999 1 Moxa 2 Mds-g516e, Mds-g516e Firmware 2020-03-30 4.0 MEDIUM 6.5 MEDIUM
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer.
CVE-2020-6983 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2020-03-26 5.0 MEDIUM 7.5 HIGH
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
CVE-2020-6987 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2020-03-26 5.0 MEDIUM 7.5 HIGH
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
CVE-2020-6989 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2020-03-26 7.5 HIGH 9.8 CRITICAL
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.