Filtered by vendor Siemens
Subscribe
Total
1529 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-13941 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2021-11-01 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in OZW672 (All versions < V10.00), OZW772 (All versions < V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. | |||||
CVE-2019-19285 | 1 Siemens | 1 Xhq | 2021-10-29 | 3.5 LOW | 5.4 MEDIUM |
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow injections that could lead to XSS attacks if unsuspecting users are tricked into accessing a malicious link. | |||||
CVE-2019-13922 | 1 Siemens | 1 Sinema Remote Connect Server | 2021-10-28 | 4.0 MEDIUM | 2.7 LOW |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
CVE-2019-10916 | 1 Siemens | 4 Simatic Pcs 7, Simatic Wincc, Simatic Wincc \(tia Portal\) and 1 more | 2021-10-28 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
CVE-2019-10918 | 1 Siemens | 4 Simatic Pcs 7, Simatic Wincc, Simatic Wincc \(tia Portal\) and 1 more | 2021-10-28 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
CVE-2019-10927 | 1 Siemens | 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more | 2021-10-28 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device. | |||||
CVE-2019-10931 | 1 Siemens | 28 6md85, 6md86, 6md89 and 25 more | 2021-10-28 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition. | |||||
CVE-2021-37199 | 1 Siemens | 4 Sinumerik 808d, Sinumerik 808d Firmware, Sinumerik 828d and 1 more | 2021-10-19 | 7.8 HIGH | 7.5 HIGH |
A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device. | |||||
CVE-2021-27395 | 1 Siemens | 4 Simatic Process Historian 2013, Simatic Process Historian 2014, Simatic Process Historian 2019 and 1 more | 2021-10-18 | 5.5 MEDIUM | 8.1 HIGH |
A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data. | |||||
CVE-2021-33736 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33735 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33734 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33733 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33732 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33730 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33731 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application. | |||||
CVE-2021-33729 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 6.5 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database. | |||||
CVE-2021-33728 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 9.0 HIGH | 7.2 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to upload JSON objects that are deserialized to JAVA objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a crafted serialized Java object. An exploit could allow the attacker to execute arbitrary code on the device with root privileges. | |||||
CVE-2021-33727 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could download the user profile of any user. With this, the attacker could leak confidential information of any user in the affected system. | |||||
CVE-2021-33726 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to download arbitrary files under a user controlled path and does not correctly check if the relative path is still within the intended target directory. |