Filtered by vendor Schneider-electric
Subscribe
Total
675 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-22732 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2023-02-06 | N/A | 7.5 HIGH |
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | |||||
CVE-2022-22731 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2023-02-06 | N/A | 9.8 CRITICAL |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | |||||
CVE-2022-0223 | 1 Schneider-electric | 1 Ecostruxure Power Commission | 2023-02-06 | N/A | 9.8 CRITICAL |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) | |||||
CVE-2021-22798 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2023-02-02 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext? ComBox (All Versions) | |||||
CVE-2022-22808 | 1 Schneider-electric | 14 Hmibscea53d1edb, Hmibscea53d1edb Firmware, Hmibscea53d1edl and 11 more | 2023-02-02 | 6.8 MEDIUM | 8.8 HIGH |
A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13) | |||||
CVE-2017-9629 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2023-02-01 | 10.0 HIGH | 9.8 CRITICAL |
A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account. | |||||
CVE-2017-9631 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2023-02-01 | 5.0 MEDIUM | 7.5 HIGH |
A Null Pointer Dereference issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The null pointer dereference vulnerability could allow an attacker to crash the logger process, causing a denial of service for logging and log-viewing (applications that use the Wonderware ArchestrA Logger continue to run when the Wonderware ArchestrA Logger service is unavailable). | |||||
CVE-2017-9627 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2023-02-01 | 5.0 MEDIUM | 8.6 HIGH |
An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service. | |||||
CVE-2018-7801 | 1 Schneider-electric | 2 Evlink Parking, Evlink Parking Firmware | 2023-02-01 | 6.8 MEDIUM | 8.8 HIGH |
A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed. | |||||
CVE-2022-22727 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2023-01-30 | 9.3 HIGH | 8.8 HIGH |
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user?s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior) | |||||
CVE-2021-22827 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2023-01-30 | 6.8 MEDIUM | 8.8 HIGH |
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions | |||||
CVE-2022-22811 | 1 Schneider-electric | 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more | 2023-01-30 | 8.8 HIGH | 8.1 HIGH |
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system?s configurations when an attacker persuades a user to visit a rogue website. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) | |||||
CVE-2021-22826 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2023-01-30 | 6.8 MEDIUM | 8.8 HIGH |
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions | |||||
CVE-2021-22737 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2023-01-19 | 5.0 MEDIUM | 9.8 CRITICAL |
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack. | |||||
CVE-2020-7561 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2022-12-12 | 7.5 HIGH | 9.8 CRITICAL |
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted. | |||||
CVE-2019-6837 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2022-11-30 | 6.4 MEDIUM | 9.1 CRITICAL |
A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could cause server configuration data to be exposed when an attacker modifies a URL. | |||||
CVE-2019-6811 | 1 Schneider-electric | 4 Modicon Quantum 140noe77101, Modicon Quantum 140noe77101 Firmware, Modicon Quantum 140noe77111 and 1 more | 2022-11-30 | 5.0 MEDIUM | 7.5 HIGH |
An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover. | |||||
CVE-2019-6835 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2022-11-30 | 3.5 LOW | 5.4 MEDIUM |
A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page. | |||||
CVE-2019-6840 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2022-11-30 | 7.5 HIGH | 9.8 CRITICAL |
A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed. | |||||
CVE-2022-0222 | 1 Schneider-electric | 28 Modicon M340 Bmxnoe0100, Modicon M340 Bmxnoe0100 Firmware, Modicon M340 Bmxnoe0110 and 25 more | 2022-11-30 | N/A | 7.5 HIGH |
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24) |