Filtered by vendor Phoenixcontact
Subscribe
Total
75 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-12517 | 1 Phoenixcontact | 7 Axc F 1152, Axc F 2152, Axc F 2152 Starterkit and 4 more | 2020-12-21 | 6.0 MEDIUM | 9.0 CRITICAL |
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an authenticated low privileged user could embed malicious Javascript code to gain admin rights when the admin user visits the vulnerable website (local privilege escalation). | |||||
CVE-2020-12523 | 1 Phoenixcontact | 18 Fl Mguard Rs4004 Tx\/dtx, Fl Mguard Rs4004 Tx\/dtx Firmware, Fl Mguard Rs4004 Tx\/dtx Vpn and 15 more | 2020-12-21 | 6.4 MEDIUM | 9.1 CRITICAL |
On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device configuration. For mGuard devices with integrated switch on the LAN side, single switch ports can be disabled by device configuration. After a reboot these ports get functional independent from their configuration setting: Missing Initialization of Resource | |||||
CVE-2020-12524 | 1 Phoenixcontact | 6 Btp 2043w, Btp 2043w Firmware, Btp 2070w and 3 more | 2020-12-04 | 5.0 MEDIUM | 7.5 HIGH |
Uncontrolled Resource Consumption can be exploited to cause the Phoenix Contact HMIs BTP 2043W, BTP 2070W and BTP 2102W in all versions to become unresponsive and not accurately update the display content (Denial of Service). | |||||
CVE-2019-10997 | 1 Phoenixcontact | 4 Axc F 2152, Axc F 2152 Firmware, Axc F 2152 Starterkit and 1 more | 2020-08-24 | 7.1 HIGH | 5.9 MEDIUM |
An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell. | |||||
CVE-2019-18352 | 1 Phoenixcontact | 4 Fl Nat 2208, Fl Nat 2208 Firmware, Fl Nat 2304-2gc-2sfp and 1 more | 2020-08-24 | 4.3 MEDIUM | 8.2 HIGH |
Improper access control exists on PHOENIX CONTACT FL NAT 2208 devices before V2.90 and FL NAT 2304-2GC-2SFP devices before V2.90 when using MAC-based port security. | |||||
CVE-2019-16675 | 1 Phoenixcontact | 3 Config\+, Pc Worx, Pc Worx Express | 2020-08-24 | 6.8 MEDIUM | 7.8 HIGH |
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation. | |||||
CVE-2018-16994 | 1 Phoenixcontact | 6 Axl F Bk Eth, Axl F Bk Eth Firmware, Axl F Bk Eth Xc and 3 more | 2020-08-24 | 7.8 HIGH | 7.5 HIGH |
An issue was discovered on PHOENIX CONTACT AXL F BK PN <=1.0.4, AXL F BK ETH <= 1.12, and AXL F BK ETH XC <= 1.11 devices and Bosch Rexroth S20-ETH-BK and Rexroth S20-PN-BK+ (the S20-PN-BK+/S20-ETH-BK fieldbus couplers sold by Bosch Rexroth contain technology from Phoenix Contact). Incorrect handling of a request with non-standard symbols allows remote attackers to initiate a complete lock up of the bus coupler. Authentication of the request is not required. | |||||
CVE-2018-13992 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2020-08-24 | 5.0 MEDIUM | 9.8 CRITICAL |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 allows for plaintext transmission (HTTP) of user credentials by default. | |||||
CVE-2020-12499 | 1 Phoenixcontact | 1 Plcnext Engineer | 2020-08-05 | 4.4 MEDIUM | 7.3 HIGH |
In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files. | |||||
CVE-2020-12498 | 1 Phoenixcontact | 2 Pc Worx, Pc Worx Express | 2020-07-10 | 6.8 MEDIUM | 7.8 HIGH |
mwe file parsing in Phoenix Contact PC Worx and PC Worx Express version 1.87 and earlier is vulnerable to out-of-bounds read remote code execution. Manipulated PC Worx projects could lead to a remote code execution due to insufficient input data validation. | |||||
CVE-2020-10940 | 1 Phoenixcontact | 3 Portico Server 16 Client, Portico Server 1 Client, Portico Server 4 Client | 2020-03-31 | 4.6 MEDIUM | 7.8 HIGH |
Local Privilege Escalation can occur in PHOENIX CONTACT PORTICO SERVER through 3.0.7 when installed to run as a service. | |||||
CVE-2020-9436 | 1 Phoenixcontact | 12 Tc Cloud Client 1002-4g, Tc Cloud Client 1002-4g Firmware, Tc Cloud Client 1002-txtx and 9 more | 2020-03-16 | 9.0 HIGH | 8.8 HIGH |
PHOENIX CONTACT TC ROUTER 3002T-4G through 2.05.3, TC ROUTER 2002T-3G through 2.05.3, TC ROUTER 3002T-4G VZW through 2.05.3, TC ROUTER 3002T-4G ATT through 2.05.3, TC CLOUD CLIENT 1002-4G through 2.03.17, and TC CLOUD CLIENT 1002-TXTX through 1.03.17 devices allow authenticated users to inject system commands through a modified POST request to a specific URL. | |||||
CVE-2020-9435 | 1 Phoenixcontact | 12 Tc Cloud Client 1002-4g, Tc Cloud Client 1002-4g Firmware, Tc Cloud Client 1002-txtx and 9 more | 2020-03-16 | 5.0 MEDIUM | 7.5 HIGH |
PHOENIX CONTACT TC ROUTER 3002T-4G through 2.05.3, TC ROUTER 2002T-3G through 2.05.3, TC ROUTER 3002T-4G VZW through 2.05.3, TC ROUTER 3002T-4G ATT through 2.05.3, TC CLOUD CLIENT 1002-4G through 2.03.17, and TC CLOUD CLIENT 1002-TXTX through 1.03.17 devices contain a hardcoded certificate (and key) that is used by default for web-based services on the device. Impersonation, man-in-the-middle, or passive decryption attacks are possible if the generic certificate is not replaced by a device-specific certificate during installation. | |||||
CVE-2018-5441 | 1 Phoenixcontact | 46 Mguard Centerport, Mguard Centerport Firmware, Mguard Core Tx Vpn and 43 more | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages. | |||||
CVE-2018-13990 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions prior to 1.35 is vulnerable to brute-force attacks, because of Improper Restriction of Excessive Authentication Attempts. | |||||
CVE-2018-13994 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is vulnerable to a denial-of-service attack by making more than 120 connections. | |||||
CVE-2018-13993 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is prone to CSRF. | |||||
CVE-2018-13991 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 leaks private information in firmware images. | |||||
CVE-2017-16743 | 1 Phoenixcontact | 58 Fl Switch 3004t-fx, Fl Switch 3004t-fx Firmware, Fl Switch 3004t-fx St and 55 more | 2019-10-02 | 10.0 HIGH | 9.8 CRITICAL |
An Improper Authorization issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32. A remote unauthenticated attacker may be able to craft special HTTP requests allowing an attacker to bypass web-service authentication allowing the attacker to obtain administrative privileges on the device. | |||||
CVE-2019-12871 | 1 Phoenixcontact | 1 Automationworx Software Suite | 2019-06-27 | 6.8 MEDIUM | 8.8 HIGH |
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation. |