Filtered by vendor Fujielectric
Subscribe
Total
61 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-3947 | 1 Fujielectric | 1 V-server | 2020-08-24 | 5.0 MEDIUM | 9.8 CRITICAL |
Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server. | |||||
CVE-2020-10646 | 1 Fujielectric | 1 V-server | 2020-04-13 | 6.8 MEDIUM | 7.8 HIGH |
Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small. | |||||
CVE-2019-18240 | 1 Fujielectric | 1 V-server | 2019-11-18 | 7.5 HIGH | 9.8 CRITICAL |
In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code. | |||||
CVE-2019-10975 | 1 Fujielectric | 2 Alpha7 Pc Loader, Alpha7 Pc Loader Firmware | 2019-10-09 | 3.3 LOW | 6.6 MEDIUM |
An out-of-bounds read vulnerability has been identified in Fuji Electric Alpha7 PC Loader Versions 1.1 and prior, which may crash the system. | |||||
CVE-2018-14819 | 1 Fujielectric | 2 V-server, V-server Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric V-Server 4.0.3.0 and prior, An out-of-bounds read vulnerability has been identified, which may allow remote code execution. | |||||
CVE-2018-14811 | 1 Fujielectric | 2 V-server, V-server Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric V-Server 4.0.3.0 and prior, Multiple untrusted pointer dereference vulnerabilities have been identified, which may allow remote code execution. | |||||
CVE-2018-14809 | 1 Fujielectric | 2 V-server, V-server Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric V-Server 4.0.3.0 and prior, A use after free vulnerability has been identified, which may allow remote code execution. | |||||
CVE-2018-14794 | 1 Fujielectric | 2 Alpha5 Smart Loader, Alpha5 Smart Loader Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. The device does not perform a check on the length/size of a project file before copying the entire contents of the file to a heap-based buffer. | |||||
CVE-2018-14802 | 1 Fujielectric | 7 Frenic-ace, Frenic-eco, Frenic-mega and 4 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution. | |||||
CVE-2018-14790 | 1 Fujielectric | 7 Frenic-ace, Frenic-eco, Frenic-mega and 4 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device. | |||||
CVE-2018-14788 | 1 Fujielectric | 2 Alpha5 Smart Loader, Alpha5 Smart Loader Firmware | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
Fuji Electric Alpha5 Smart Loader Versions 3.7 and prior. A buffer overflow information disclosure vulnerability occurs when parsing certain file types. | |||||
CVE-2018-14798 | 1 Fujielectric | 7 Frenic-ace, Frenic-eco, Frenic-mega and 4 more | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure. | |||||
CVE-2018-14817 | 1 Fujielectric | 2 V-server, V-server Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric V-Server 4.0.3.0 and prior, An integer underflow vulnerability has been identified, which may allow remote code execution. | |||||
CVE-2018-14812 | 1 Fujielectric | 1 Energy Savings Estimator | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
An uncontrolled search path element (DLL Hijacking) vulnerability has been identified in Fuji Electric Energy Savings Estimator versions V.1.0.2.0 and prior. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL. | |||||
CVE-2018-10637 | 1 Fujielectric | 1 V-server | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. | |||||
CVE-2017-9639 | 1 Fujielectric | 1 V-server | 2019-10-09 | 7.5 HIGH | 7.3 HIGH |
An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution. | |||||
CVE-2017-9662 | 1 Fujielectric | 1 Monitouch V-sft | 2019-10-02 | 4.6 MEDIUM | 5.3 MEDIUM |
An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. Monitouch V-SFT is installed in a directory with weak access controls by default, which could allow an authenticated attacker with local access to escalate privileges. | |||||
CVE-2019-3946 | 1 Fujielectric | 1 V-server | 2019-06-14 | 5.0 MEDIUM | 7.5 HIGH |
Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. An unauthenticated, remote attacker can crash vserver.exe due to an integer overflow in the UDP message handling logic. | |||||
CVE-2018-14815 | 1 Fujielectric | 2 V-server, V-server Firmware | 2018-11-16 | 7.5 HIGH | 9.8 CRITICAL |
Fuji Electric V-Server 4.0.3.0 and prior, Several out-of-bounds write vulnerabilities have been identified, which may allow remote code execution. | |||||
CVE-2017-9659 | 1 Fujielectric | 1 Monitouch V-sft | 2017-08-24 | 6.8 MEDIUM | 8.8 HIGH |
A Stack-Based Buffer Overflow issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. The stack-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution. |