Filtered by vendor Google
Subscribe
Total
10294 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-0137 | 1 Google | 2 Chrome, Chrome Os | 2023-01-13 | N/A | 8.8 HIGH |
Heap buffer overflow in Platform Apps in Google Chrome on Chrome OS prior to 109.0.5414.74 allowed an attacker who convinced a user to install a malicious extension to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: Medium) | |||||
CVE-2023-0138 | 1 Google | 1 Chrome | 2023-01-13 | N/A | 8.8 HIGH |
Heap buffer overflow in libphonenumber in Google Chrome prior to 109.0.5414.74 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page. (Chromium security severity: Low) | |||||
CVE-2023-0132 | 2 Google, Microsoft | 2 Chrome, Windows | 2023-01-13 | N/A | 6.5 MEDIUM |
Inappropriate implementation in in Permission prompts in Google Chrome on Windows prior to 109.0.5414.74 allowed a remote attacker to force acceptance of a permission prompt via a crafted HTML page. (Chromium security severity: Medium) | |||||
CVE-2023-0135 | 1 Google | 1 Chrome | 2023-01-13 | N/A | 8.8 HIGH |
Use after free in Cart in Google Chrome prior to 109.0.5414.74 allowed an attacker who convinced a user to install a malicious extension to potentially exploit heap corruption via database corruption and a crafted HTML page. (Chromium security severity: Medium) | |||||
CVE-2023-0134 | 1 Google | 1 Chrome | 2023-01-13 | N/A | 8.8 HIGH |
Use after free in Cart in Google Chrome prior to 109.0.5414.74 allowed an attacker who convinced a user to install a malicious extension to potentially exploit heap corruption via database corruption and a crafted HTML page. (Chromium security severity: Medium) | |||||
CVE-2023-0133 | 1 Google | 2 Android, Chrome | 2023-01-13 | N/A | 6.5 MEDIUM |
Inappropriate implementation in in Permission prompts in Google Chrome on Android prior to 109.0.5414.74 allowed a remote attacker to bypass main origin permission delegation via a crafted HTML page. (Chromium security severity: Medium) | |||||
CVE-2022-44426 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 5.5 MEDIUM |
In wlan driver, there is a possible missing bounds check. This could lead to local denial of service in wlan services. | |||||
CVE-2022-44427 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 5.5 MEDIUM |
In wlan driver, there is a possible missing bounds check. This could lead to local denial of service in wlan services. | |||||
CVE-2022-44428 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 5.5 MEDIUM |
In wlan driver, there is a possible missing bounds check. This could lead to local denial of service in wlan services. | |||||
CVE-2022-44429 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 5.5 MEDIUM |
In wlan driver, there is a possible missing bounds check. This could lead to local denial of service in wlan services. | |||||
CVE-2022-39099 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39096 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39095 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39097 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39098 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39094 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39102 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39101 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-39100 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. | |||||
CVE-2022-42777 | 2 Google, Unisoc | 14 Android, S8000, Sc7731e and 11 more | 2023-01-10 | N/A | 7.8 HIGH |
In power management service, there is a missing permission check. This could lead to set up power management service with no additional execution privileges needed. |