Total
101 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-6552 | 1 Advantech | 1 Webaccess | 2020-10-06 | 7.5 HIGH | 9.8 CRITICAL |
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution. | |||||
CVE-2019-6550 | 1 Advantech | 1 Webaccess | 2020-10-06 | 7.5 HIGH | 9.8 CRITICAL |
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution. | |||||
CVE-2018-7499 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2020-10-02 | 7.5 HIGH | 9.8 CRITICAL |
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several stack-based buffer overflow vulnerabilities have been identified, which may allow an attacker to execute arbitrary code. | |||||
CVE-2020-16202 | 1 Advantech | 1 Webaccess | 2020-09-30 | 7.2 HIGH | 7.8 HIGH |
WebAccess Node (All versions prior to 9.0.1) has incorrect permissions set for resources used by specific services, which may allow code execution with system privileges. | |||||
CVE-2018-8845 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2020-09-29 | 7.5 HIGH | 9.8 CRITICAL |
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code. | |||||
CVE-2018-14816 | 1 Advantech | 1 Webaccess | 2020-08-28 | 7.5 HIGH | 9.8 CRITICAL |
Advantech WebAccess 8.3.1 and earlier has several stack-based buffer overflow vulnerabilities that have been identified, which may allow an attacker to execute arbitrary code. | |||||
CVE-2019-3953 | 1 Advantech | 1 Webaccess | 2020-08-24 | 7.5 HIGH | 9.8 CRITICAL |
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10012 RPC call. | |||||
CVE-2019-3941 | 1 Advantech | 1 Webaccess | 2020-08-24 | 6.4 MEDIUM | 7.5 HIGH |
Advantech WebAccess 8.3.4 allows unauthenticated, remote attackers to delete arbitrary files via IOCTL 10005 RPC. | |||||
CVE-2019-3954 | 1 Advantech | 1 Webaccess | 2020-08-24 | 7.5 HIGH | 9.8 CRITICAL |
Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81024 RPC call. | |||||
CVE-2018-15704 | 1 Advantech | 1 Webaccess | 2020-08-24 | 9.0 HIGH | 8.8 HIGH |
Advantech WebAccess 8.3.2 and below is vulnerable to a stack buffer overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability by sending a crafted HTTP request to broadweb/system/opcImg.asp. | |||||
CVE-2020-12014 | 1 Advantech | 1 Webaccess | 2020-05-11 | 5.0 MEDIUM | 7.5 HIGH |
Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Input is not properly sanitized and may allow an attacker to inject SQL commands. | |||||
CVE-2020-12018 | 1 Advantech | 1 Webaccess | 2020-05-11 | 5.0 MEDIUM | 7.5 HIGH |
Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. An out-of-bounds vulnerability exists that may allow access to unauthorized data. | |||||
CVE-2020-12022 | 1 Advantech | 1 Webaccess | 2020-05-11 | 7.5 HIGH | 9.8 CRITICAL |
Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. An improper validation vulnerability exists that could allow an attacker to inject specially crafted input into memory where it can be executed. | |||||
CVE-2019-3942 | 1 Advantech | 1 Webaccess | 2020-04-02 | 5.0 MEDIUM | 7.5 HIGH |
Advantech WebAccess 8.3.4 does not properly restrict an RPC call that allows unauthenticated, remote users to read files. An attacker can use this vulnerability to recover the administrator password. | |||||
CVE-2020-10607 | 1 Advantech | 1 Webaccess | 2020-04-01 | 6.5 MEDIUM | 8.8 HIGH |
In Advantech WebAccess, Versions 8.4.2 and prior. A stack-based buffer overflow vulnerability caused by a lack of proper validation of the length of user-supplied data may allow remote code execution. | |||||
CVE-2019-3951 | 1 Advantech | 1 Webaccess | 2019-12-18 | 7.5 HIGH | 9.8 CRITICAL |
Advantech WebAccess before 8.4.3 allows unauthenticated remote attackers to execute arbitrary code or cause a denial of service (memory corruption) due to a stack-based buffer overflow when handling IOCTL 70533 RPC messages. | |||||
CVE-2019-3940 | 1 Advantech | 1 Webaccess | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
Advantech WebAccess 8.3.4 is vulnerable to file upload attacks via unauthenticated RPC call. An unauthenticated, remote attacker can use this vulnerability to execute arbitrary code. | |||||
CVE-2019-13558 | 1 Advantech | 1 Webaccess | 2019-10-09 | 9.0 HIGH | 9.8 CRITICAL |
In WebAccess versions 8.4.1 and prior, an exploit executed over the network may cause improper control of generation of code, which may allow remote code execution, data exfiltration, or cause a system crash. | |||||
CVE-2018-7497 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several untrusted pointer dereference vulnerabilities have been identified, which may allow an attacker to execute arbitrary code. | |||||
CVE-2018-7501 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several SQL injection vulnerabilities have been identified, which may allow an attacker to disclose sensitive information from the host. |